EUVIMEDEUVIMED entdecken
Crossref

Electroanalytical method development for the receptor tyrosine kinase inhibitor lenvatinib using a Ti3C2Tx-MXene based molecularly imprinted polymer modified carbon electrode

Mehmet Gülcan, Pınar Talay Pınar

Analytical and Bioanalytical Chemistry · 2026

DOI: 10.1007/s00216-026-06646-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2026. Verfasst von Mehmet Gülcan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, Van Yuzuncu Yil University, Zeve Campus, 65080, Van, Turkey. Hauptthemen laut MEDLINE: Quinolines, Phenylurea Compounds, Electrochemical Techniques, Protein Kinase Inhibitors. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a Ti3C2Tx-MXene-based molecularly imprinted polymer sensor (MX/GCE-MiP) was developed for the electrochemical determination of the tyrosine kinase inhibitor lenvatinib. By combining the high surface area and conductivity of Ti3C2Tx-MXene with the selective recognition properties of molecularly imprinted polymers, a sensitive electrochemical sensing platform was obtained. The analytical performance of the sensor was evaluated by square-wave voltammetry (SWV) using the [Fe(CN)6]-3/-4 redox probe system after rebinding of lenvatinib within the imprinted cavities. Under optimized experimental conditions, the proposed sensor exhibited a linear response in the concentration range of 5.0-30.0 nM with a limit of detection (LOD) of 0.29 nM. Selectivity studies performed in the presence of dopamine, uric acid, ascorbic acid, and futibatinib demonstrated a significantly higher response toward lenvatinib under identical experimental conditions. In addition, the sensor showed good repeatability (3.20%), reproducibility (3.65%), and storage stability (4.1%). The applicability of the proposed sensor was preliminarily evaluated in synthetic serum and urine samples, yielding acceptable recovery values. Overall, the developed MX/GCE-MIP sensor provides a simple, sensitive, and cost-effective platform for the electrochemical detection of lenvatinib.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

QuinolinesPhenylurea CompoundsElectrochemical TechniquesProtein Kinase InhibitorsCarbonMolecularly Imprinted PolymersTitaniumReceptor Protein-Tyrosine KinasesPolymersElectrodesLimit of DetectionHumansReproducibility of ResultsNitritesTransition Elements

Stichwörter der Autor:innen

Electrochemical sensorLenvatinibMolecularly imprinted polymerSquare-wave voltammetryTi3C2Tx-MXeneTyrosine kinase inhibitor

Substanzen

QuinolinesPhenylurea CompoundslenvatinibProtein Kinase InhibitorsCarbonMolecularly Imprinted PolymersTitaniumReceptor Protein-Tyrosine KinasesPolymersMXene

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Science, Van Yuzuncu Yil University, Zeve Campus, 65080, Van, Turkey.
  • Department of Analytical Chemistry, Faculty of Pharmacy, Van Yuzuncu Yil University, Zeve Campus, 65080, Van, Turkey. ptalay@gmail.com.

Zitieren

APA

Gülcan, M., & Talay Pınar, P. (2026). Electroanalytical method development for the receptor tyrosine kinase inhibitor lenvatinib using a Ti3C2Tx-MXene based molecularly imprinted polymer modified carbon electrode. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-026-06646-4

Vancouver

Gülcan M, Talay Pınar P. Electroanalytical method development for the receptor tyrosine kinase inhibitor lenvatinib using a Ti3C2Tx-MXene based molecularly imprinted polymer modified carbon electrode. Analytical and Bioanalytical Chemistry. 2026. doi:10.1007/s00216-026-06646-4

BibTeX
@article{Glcan2026,
  author = {Gülcan, Mehmet and Talay Pınar, Pınar},
  title = {Electroanalytical method development for the receptor tyrosine kinase inhibitor lenvatinib using a Ti3C2Tx-MXene based molecularly imprinted polymer modified carbon electrode},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2026},
  doi = {10.1007/s00216-026-06646-4}
}