Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 03.10.2024. Verfasst von Anabel Villalonga und 5 weiteren Autor:innen. Beteiligte Einrichtung: Nanosensors and Nanomachines Group, Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040, Madrid, Spain. Hauptthemen laut MEDLINE: Nanotubes, Carbon, Electrodes, Electrochemical Techniques, Glutathione Reductase. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Agencia Estatal de Investigación.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The preparation of a hybrid nanomaterial is reported by covalently attaching 3,5-dinitrobenzoic acid groups to the surface of oxidized multi-walled carbon nanotubes using 1,6-diaminohexane as cross-linking agent. This nanomaterial, modified with the redox mediator, was used as transduction element to construct an amperometric sensor for the efficient indirect determination of glutathione reductase at a low working potential of - 0.05 V, through the oxidation of unconsumed nicotinamide adenine dinucleotide phosphate (NADPH) in the enzymatic reaction. The sensor exhibited an excellent linear response in the range 1.6 to 174 µU/µL, with high reproducibility and selectivity. The developed device was successfully validated in real samples, accurately determining the active enzyme in diluted human serum, making it a promising alternative for the determination of glutathione reductase and other related NADPH-dependent enzymes with relevance in clinical analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nanotubes, CarbonElectrodesElectrochemical TechniquesGlutathione ReductaseHumansBiosensing TechniquesNADPOxidation-ReductionNitrobenzoatesLimit of Detection

Stichwörter der Autor:innen

AmperometryCarbon nanotubesGlutathione reductaseHybrid nanomaterialNADPHSensor

Substanzen

Nanotubes, CarbonGlutathione ReductaseNADPNitrobenzoates

Autor:innen und Institutionen

  • Nanosensors and Nanomachines Group, Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040, Madrid, Spain.
  • Nanosensors and Nanomachines Group, Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040, Madrid, Spain. rvillalonga@quim.ucm.es.
  • Nanosensors and Nanomachines Group, Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040, Madrid, Spain. ireojeda@ucm.es.
  • Department of Chemistry in Pharmaceutical Sciences, Analytical Chemistry, Faculty of Pharmacy, Complutense University of Madrid, 28040, Madrid, Spain. ireojeda@ucm.es.

Förderung

  • Agencia Estatal de Investigación

Zitieren

APA

Villalonga, A., López-López, D., García-Díez, E., Sánchez, A., Villalonga, R., & Ojeda, I. (2024). Electrochemical sensor for glutathione reductase based on screen-printed electrodes coated with 3,5-dinitrobenzoic acid-modified carbon nanotubes. Microchimica Acta, 191(11). https://doi.org/10.1007/s00604-024-06728-z

Vancouver

Villalonga A, López-López D, García-Díez E, Sánchez A, Villalonga R, Ojeda I. Electrochemical sensor for glutathione reductase based on screen-printed electrodes coated with 3,5-dinitrobenzoic acid-modified carbon nanotubes. Microchimica Acta. 2024;191(11). doi:10.1007/s00604-024-06728-z

BibTeX
@article{Villalonga2024,
  author = {Villalonga, Anabel and López-López, David and García-Díez, Esther and Sánchez, Alfredo and Villalonga, Reynaldo and Ojeda, Irene},
  title = {Electrochemical sensor for glutathione reductase based on screen-printed electrodes coated with 3,5-dinitrobenzoic acid-modified carbon nanotubes},
  journal = {Microchimica Acta},
  year = {2024},
  volume = {191},
  number = {11},
  doi = {10.1007/s00604-024-06728-z}
}
Kostenlos starten →