EUVIMEDEUVIMED entdecken
Crossref

Eu3+-functionalized covalent organic framework for ratiometric fluorescence detection and adsorption of tetracycline and information steganography

Qing-Hong Long, Li-Na Hong, Chun Han, Xin-Yuan Li, Yi-Jing Liao, Xi-Luan Yan, Xi Mai, Na Li

Microchimica Acta · 2024

DOI: 10.1007/s00604-024-06584-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Qing-Hong Long und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China. Hauptthemen laut MEDLINE: Europium, Metal-Organic Frameworks, Tetracycline, Limit of Detection. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Jiangxi Province, TCM Science and Technology Project of Jiangxi Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Functional materials with organic/inorganic composites as the main matrix and rare earth ion complexes as the guest have shown a very broad application prospect for antibiotic sensors. However, Eu3+-complex often relies on a single fluorescence response signal, which is susceptible to changes in the detection environment and cannot simultaneously detect and remove tetracycline (TC). Herein, green fluorescent covalent two-dimensional organic framework (COF-TD) is synthesized, followed by modification of Eu3+ to synthesize COF-TD@Eu3+. In the ratiometric sensor, Eu3+ serves as the recognition site and specific response probe for TC, while COF-TD is the fluorescence reference and carrier for Eu3+. Due to the antenna effect, TC enhances the red fluorescence of Eu3+, while the green fluorescence of COF-TD remains almost stable. Based on the change of fluorescence intensity and fluorescence color from green to red, the efficient ratiometric sensing can be finished in 1 min. The developed method shows high sensitivity with a detection limit of 0.3 μM and high selectivity to TC which makes the method applicable to detect TC in traditional Chinese medicine preparations. In addition, due to the high specific surface area of COFs and specific adsorption sites, COF-TD@Eu3+ also shows good performance for TC removal. The findings show that the maximum adsorption capacity is 137.3 mg g-1 and the adsorption equilibrium is reached in 30 min. Smartphone assisted COF-TD@Eu3+ for both ratiometric fluorescence detection and detecting the absorption of TC is proposed for the first time. The molecular cryptosteganography that transforms the selective response of COF-TD@Eu3+ to binary strings is anticipated to advance utilization of nanomaterials in logic sensing and information safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EuropiumMetal-Organic FrameworksTetracyclineLimit of DetectionSpectrometry, FluorescenceFluorescent DyesAdsorptionWater Pollutants, ChemicalAnti-Bacterial AgentsFluorescence

Stichwörter der Autor:innen

Covalent organic frameworkInformation steganographyRatiometric fluorescence detectionTetracycline

Substanzen

EuropiumMetal-Organic FrameworksTetracyclineFluorescent DyesWater Pollutants, ChemicalAnti-Bacterial Agents

Autor:innen und Institutionen

  • School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China.
  • Nanchang Center for Disease Control and Prevention, The Collaboration Unit for Field Epidemiology of State Key Laboratory for Infectious Disease Control and Prevention, Nanchang, Jiangxi, 330038, People's Republic of Ch…
  • School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China. maixi123@aliyun.com.
  • School of Pharmaceutical Science, Nanchang University, Nanchang, 330006, People's Republic of China. lin@ncu.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Jiangxi Province
  • TCM Science and Technology Project of Jiangxi Province

Zitieren

APA

Long, Q. H., Hong, L. N., Han, C., Li, X. Y., Liao, Y. J., Yan, X. L., Mai, X., & Li, N. (2024). Eu3+-functionalized covalent organic framework for ratiometric fluorescence detection and adsorption of tetracycline and information steganography. Microchimica Acta. https://doi.org/10.1007/s00604-024-06584-x

Vancouver

Long QH, Hong LN, Han C, Li XY, Liao YJ, Yan XL, et al. Eu3+-functionalized covalent organic framework for ratiometric fluorescence detection and adsorption of tetracycline and information steganography. Microchimica Acta. 2024. doi:10.1007/s00604-024-06584-x

BibTeX
@article{Long2024,
  author = {Long, Qing-Hong and Hong, Li-Na and Han, Chun and Li, Xin-Yuan and Liao, Yi-Jing and Yan, Xi-Luan and Mai, Xi and Li, Na},
  title = {Eu3+-functionalized covalent organic framework for ratiometric fluorescence detection and adsorption of tetracycline and information steganography},
  journal = {Microchimica Acta},
  year = {2024},
  doi = {10.1007/s00604-024-06584-x}
}
Kostenlos starten →