SERS biosensor with plastic antibodies for detection of a cancer biomarker protein
Microchimica Acta · 2024-05 · 191 (5)
DOI: 10.1007/s00604-024-06327-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 04.04.2024. Verfasst von Daniela Oliveira und 2 weiteren Autor:innen. Beteiligte Einrichtung: CIETI - LabRISE-School of Engineering, Polytechnic of Porto, R. Dr. António Bernardino de Almeida, 431, 4249-015, Porto, Portugal. Hauptthemen laut MEDLINE: Molecular Imprinting, Biosensing Techniques, Neoplasms. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PhD grant (FCT), Instituto Politécnico do Porto.
Abstract (Originalsprache)
Surface-enhanced Raman scattering (SERS) is a powerful method for detecting breast cancer-specific biomarkers due to its extraordinary enhancement effects obtained by localized surface plasmon resonance (LSPR) in metallic nanostructures at hotspots. In this research, gold nanostars (AuNSs) were used as SERS probes to detect a cancer biomarker at very low concentrations. To this end, we combined molecularly imprinted polymers (MIPs) as a detection layer with SERS for the detection of the biomarker CA 15–3 in point-of-care (PoC) analysis. This required two main steps: (i) the deposition of MIPs on a gold electrode, followed by a second step (ii) antibody binding with AuNSs containing a suitable Raman reporter to enhance Raman signaling (SERS). The MPan sensor was prepared by electropolymerization of the monomer aniline in the presence of CA 15–3. The template molecule was then extracted from the polymer using sodium dodecyl sulfate (SDS). In parallel, a control material was prepared in the absence of the protein (NPan). Surface modification for the control was performed using electrochemical techniques such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The performance of the sensor was evaluated using the SERS technique, in which the MPan sensor is first incubated with the protein and then exposed to the SERS probe. Under optimized conditions, the device showed a linear response to CA 15–3 concentrations from 0.016 to 248.51 U mL −1 in a PBS buffer at pH 7.4 in 1000-fold diluted serum. Overall, this approach demonstrates the potential of SERS as an optical reader and opens a new avenue for biosensing applications. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- CIETI - LabRISE-School of Engineering, Polytechnic of Porto, R. Dr. António Bernardino de Almeida, 431, 4249-015, Porto, Portugal.
- CIETI - LabRISE-School of Engineering, Polytechnic of Porto, R. Dr. António Bernardino de Almeida, 431, 4249-015, Porto, Portugal. ftm@isep.ipp.pt.
Förderung
- PhD grant (FCT)
- Instituto Politécnico do Porto
Zitieren
APA
Oliveira, D., Carneiro, M. C. C. G., & Moreira, F. T. C. (2024). SERS biosensor with plastic antibodies for detection of a cancer biomarker protein. Microchimica Acta, 191(5). https://doi.org/10.1007/s00604-024-06327-y
Vancouver
Oliveira D, Carneiro MCCG, Moreira FTC. SERS biosensor with plastic antibodies for detection of a cancer biomarker protein. Microchimica Acta. 2024;191(5). doi:10.1007/s00604-024-06327-y
BibTeX
@article{Oliveira2024,
author = {Oliveira, Daniela and Carneiro, Mariana C C G and Moreira, Felismina T C},
title = {SERS biosensor with plastic antibodies for detection of a cancer biomarker protein},
journal = {Microchimica Acta},
year = {2024},
volume = {191},
number = {5},
doi = {10.1007/s00604-024-06327-y}
}
EUVIMED