Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023. Verfasst von Zhenjiao Shang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China. Hauptthemen laut MEDLINE: Biosensing Techniques, Metal Nanoparticles. Die Arbeit wurde bisher 77-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasensitive determination of tumor marker (TM) is of great significance in cancer prevention and diagnosis. Traditional TM detection methods involve large instrumentation and professional manipulation, which complicate the assay procedures and increase the cost of investment. To resolve these problems, an integrated electrochemical immunosensor based on the flexible polydimethylsiloxane/gold (PDMS/Au) film with Fe-Co metal-organic framework (Fe-Co MOF) as a signal amplifier was fabricated for ultrasensitive determination of alpha fetoprotein (AFP). First, gold layer was deposited on the hydrophilic PDMS film to form the flexible three-electrode system, and then the thiolated aptamer for AFP was immobilized. Afterward, the aminated Fe-Co MOF possessing high peroxidase-like activity and large specific surface area was prepared by a facile solvothermal method, and subsequently the biofunctionalized MOF could effectively capture biotin antibody (Ab) to form MOF-Ab as a signal probe and amplify the electrochemical signal remarkably, thereby realizing highly sensitive detection of AFP with a wide linear range of 0.01-300 ng/mL and a low detection limit of 0.71 pg/mL. In addition, the PDMS based-immunosensor showed good accuracy for assaying of AFP in clinical serum samples. The integrated and flexible electrochemical immunosensor based on the Fe-Co MOF as a signal amplifier demonstrates great potential for application in the personalized point-of-care (POC) clinical diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMetal Nanoparticlesalpha-FetoproteinsLimit of DetectionImmunoassayBiomarkers, TumorAntibodiesGoldElectrochemical Techniques

Stichwörter der Autor:innen

Alpha-fetoproteinFe–Co metal-organic frameworkIntegrated electrochemical immunosensorPoint-of-care testing

Substanzen

alpha-FetoproteinsBiomarkers, TumorAntibodiesGold

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China.
  • Department of Chemical Engineering, Yangzhou Polytechnic Institute, Yangzhou, 225002, PR China.
  • School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China. Electronic address: shuyun@yzu.edu.cn.

Zitieren

APA

Shang, Z., Su, T., Jin, D., Xu, Q., Hu, X., & Shu, Y. (2023). An integrated and flexible PDMS/Au film-based electrochemical immunosensor via Fe–Co MOF as a signal amplifier for alpha fetoprotein detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2023.115245

Vancouver

Shang Z, Su T, Jin D, Xu Q, Hu X, Shu Y. An integrated and flexible PDMS/Au film-based electrochemical immunosensor via Fe–Co MOF as a signal amplifier for alpha fetoprotein detection. Biosensors and Bioelectronics. 2023. doi:10.1016/j.bios.2023.115245

BibTeX
@article{Shang2023,
  author = {Shang, Zhenjiao and Su, Tong and Jin, Dangqin and Xu, Qin and Hu, Xiaoya and Shu, Yun},
  title = {An integrated and flexible PDMS/Au film-based electrochemical immunosensor via Fe–Co MOF as a signal amplifier for alpha fetoprotein detection},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  doi = {10.1016/j.bios.2023.115245}
}
Kostenlos starten →