Detection of tumor marker CA72-4 with an electrochemical immunosensor based on MnO2 nanosheets and HNM-AuPtPd nanocomposites
Microchimica Acta · 2024
DOI: 10.1007/s00604-024-06266-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Qinghua Yan und 4 weiteren Autor:innen. Beteiligte Einrichtung: The Key Laboratory of Biomedical Material, School of Life Science and Technology, Xinxiang Medical University, Xinxiang, 453003, China. yqh3499@163.c…. Hauptthemen laut MEDLINE: Biosensing Techniques, Nanocomposites, Antigens, Tumor-Associated, Carbohydrate. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
To accurately detect tumor marker carbohydrate antigen 72-4 (CA72-4) of serum samples is of great significance for the early diagnosis of malignant tumors. In the present study, MnO2/hollow nanobox metal-organic framework (HNM)-AuPtPd nanocomposites were prepared via multi-step synthesis and superposition method and a series of characterizations were carried out. A highly sensitive immunosensor Ab/MnO2/HNM-AuPtPd/GCE based on the composite nanomaterial was further prepared and used to detect the tumor marker CA72-4. The constructed immunosensor achieved signal amplification by increasing the electrocatalytic activity to H2O2 by means of the synergistic effect of MnO2 ultra-thin nanosheets (MnO2 UNs) and HNM-AuPtPd. At the same time, the electrochemical properties of the immunosensor were analyzed using cyclic voltammetry, electrochemical impedance, amperometry (with the test voltage of -0.4 V), and differential pulse voltammetry. The experimental results showed that the MnO2/HNM-AuPtPd nanocomposites were successfully prepared, and the immunosensor Ab/MnO2/HNM-AuPtPd/GCE demonstrated an excellent electrochemical performance. The electrochemical immunosensor had the highest detection sensitivity under the optimal experimental conditions, such as incubation pH of 7.0, incubation time of 60 min, with the addition of 15 μL of H2O2, and in the concentration range 0.001-500 U/mL. It had a low detection limit of 1.78×10-5 U/mL (S/N = 3). Moreover, the serum sample recovery were in the range from 99.38 to 100.52%. This study provides a new method and experimental basis for the detection of tumor markers in clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- The Key Laboratory of Biomedical Material, School of Life Science and Technology, Xinxiang Medical University, Xinxiang, 453003, China. yqh3499@163.com.
- The Key Laboratory of Biomedical Material, School of Life Science and Technology, Xinxiang Medical University, Xinxiang, 453003, China.
Zitieren
APA
Yan, Q., Wu, R., Wang, J., Mao, J., & Nan, W. (2024). Detection of tumor marker CA72-4 with an electrochemical immunosensor based on MnO2 nanosheets and HNM-AuPtPd nanocomposites. Microchimica Acta. https://doi.org/10.1007/s00604-024-06266-8
Vancouver
Yan Q, Wu R, Wang J, Mao J, Nan W. Detection of tumor marker CA72-4 with an electrochemical immunosensor based on MnO2 nanosheets and HNM-AuPtPd nanocomposites. Microchimica Acta. 2024. doi:10.1007/s00604-024-06266-8
BibTeX
@article{Yan2024,
author = {Yan, Qinghua and Wu, Ruixue and Wang, Jiaxin and Mao, Jian and Nan, Wenbin},
title = {Detection of tumor marker CA72-4 with an electrochemical immunosensor based on MnO2 nanosheets and HNM-AuPtPd nanocomposites},
journal = {Microchimica Acta},
year = {2024},
doi = {10.1007/s00604-024-06266-8}
}
EUVIMED