EUVIMEDEUVIMED entdecken
Crossref

Non-enzymatic paper-based analytical device for direct potentiometric detection of urine creatinine

Ayman H Kamel, Hisham S M Abd-Rabboh, Majed A Bajaber

Microchimica Acta · 2024

DOI: 10.1007/s00604-024-06203-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Ayman H Kamel und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of chemistry, College of Science, University of Bahrain, Sakhir, 32038, Kingdom of Bahrain. ahkamel76@sci.asu.edu.eg. Hauptthemen laut MEDLINE: Urinalysis. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Ministry of Advanced Education, Skills and TrainingDeputyship for Research & Innovation, Ministry of Education in Saudi Arabia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A paper-based analytical device (PAD) with an integrated composite electrode has been designed and fabricated for non-enzymatic creatinine sensing. Reduced graphene oxide (rGO) was employed to modify the PAD so that it could function as a solid-contact transducer. A new macrocyclic pyrido-hexapeptide derivative was made and used as a special ionophore in the creatinine membrane sensor. The synthesized PAD showed a detection limit of 1.0 µM (S/N = 3) and a potentiometric response towards creatinine throughout a log-linear range of 2.0 µM-10 mM (R2 = 0.9998). The sensor shows significant selectivity for a few related substances, including ephedrine, codeine, ketamine, caffeine, urea, urate, carbinoxamine, and dextromethorphan. It has been established that the testing method is appropriate for the direct potentiometric detection of creatinine in a variety of human urine sample types. When an indicating electrode and a reference electrode are put on the same flexible disposable, this lets applications with a small sample volume be done. For point-of-care creatinine measurement, the developed paper-based analytical equipment is a good choice because it is affordable, easily accessible, and self-pumping (especially when combined with potentiometric detection).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UrinalysisHumansCreatininePotentiometryElectrodes

Stichwörter der Autor:innen

Carbon nanotube inkPaper-based analytical devicePoint-of-carePotentiometric sensorsUrine creatinine

Substanzen

Creatinine

Autor:innen und Institutionen

  • Department of chemistry, College of Science, University of Bahrain, Sakhir, 32038, Kingdom of Bahrain. ahkamel76@sci.asu.edu.eg.
  • Chemistry Department, Faculty of Science, Ain Shams University, Cairo, 11566, Egypt. ahkamel76@sci.asu.edu.eg.
  • Chemistry Department, Faculty of Science, King Khalid University, 62529, Abha, Saudi Arabia.

Förderung

  • Ministry of Advanced Education, Skills and TrainingDeputyship for Research & Innovation, Ministry of Education in Saudi Arabia

Zitieren

APA

Kamel, A. H., Abd-Rabboh, H. S. M., & Bajaber, M. A. (2024). Non-enzymatic paper-based analytical device for direct potentiometric detection of urine creatinine. Microchimica Acta. https://doi.org/10.1007/s00604-024-06203-9

Vancouver

Kamel AH, Abd-Rabboh HSM, Bajaber MA. Non-enzymatic paper-based analytical device for direct potentiometric detection of urine creatinine. Microchimica Acta. 2024. doi:10.1007/s00604-024-06203-9

BibTeX
@article{Kamel2024,
  author = {Kamel, Ayman H and Abd-Rabboh, Hisham S M and Bajaber, Majed A},
  title = {Non-enzymatic paper-based analytical device for direct potentiometric detection of urine creatinine},
  journal = {Microchimica Acta},
  year = {2024},
  doi = {10.1007/s00604-024-06203-9}
}
Kostenlos starten →