Fachartikel in der Zeitschrift Acta Diabetologica, online erschienen am 15.04.2026. Verfasst von Elena Succurro und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical and Surgical Sciences, University Magna Graecia of Catanzaro, Viale Europa, Catanzaro, 88100, Italy. succurro@unicz.it. Hauptthemen laut MEDLINE: Insulin, Renal Dialysis, Diabetes Mellitus, Type 2, Insulin Infusion Systems. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli studi "Magna Graecia" di Catanzaro.
Themen: Diabetes mellitus
Abstract (Originalsprache)
Aims
To describe the main glycemic outcomes and the Quality of Life (QOL) observed in a cohort of people with type 1 (T1D) or type 2 (T2D) insulin-treated diabetes under dialysis who started an Automated Insulin Delivery (AID) system.
Methods
This is a longitudinal retrospective pilot real-world analysis of 14 individuals with T1D and T2D undergoing dialysis who began using an AID system to optimize glycemic control. All subjects used the MiniMed™ 780G system. Glucose metrics were collected at baseline, 3, 6, and 12 months after initiating the SmartGuard™ feature. The WHOQoL-Bref questionnaire was administered at the last follow-up to evaluate the QOL.
Results
Out of the 14 people, 8 reached 1-year follow-up. Time in Range (TIR) increased from 63% at baseline to 69% at 12 months, Time Below Range < 70 mg/dL (TBR70) decreased from 0.3% to 0%, and Time Above Range > 250 mg/dL (TAR250) decreased from 6.7% to 3.9%. Seven out of eight subjects who reached a 12-month follow-up achieved all three glycemic targets for this fragile population (TIR > 50%, TBR70 < 1% and TAR250 < 10%). At the last follow-up, 58.3% of the users were satisfied or very satisfied with their health status, versus only 25% with the previous treatment, and 81.7% had a good or very good QOL, whereas only 8.3% had a good QOL, and no one had a very good QOL with the previous treatment.
Conclusion
This pilot real-world study showed how the use of an AID system is safe and can help to improve the glycemic outcomes and the QOL of people with diabetes in dialysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical and Surgical Sciences, University Magna Graecia of Catanzaro, Viale Europa, Catanzaro, 88100, Italy. succurro@unicz.it.
- Research Center for the Prevention and Treatment of Metabolic Diseases (CR METDIS), University Magna Graecia of Catanzaro, Catanzaro, Italy. succurro@unicz.it.
- Azienda Ospedaliera Annunziata Cosenza, Cosenza, Italy.
- ASL Viterbo, Viterbo, Italy.
- Department of Medical and Surgical Sciences, University Magna Graecia of Catanzaro, Viale Europa, Catanzaro, 88100, Italy.
- ASP Catanzaro, Catanzaro, Italy.
Förderung
- Università degli studi "Magna Graecia" di Catanzaro
Zitieren
APA
Succurro, E., Cersosimo, G., Sarnelli, P., Brisinda, F., Gattuso, I., Mazza, V., Fabiano, G., Iorio, F., Arena, R., Mazzitello, G., Nicotera, R., Capria, M., Zaza, G., Andreucci, M., Mancini, R., & Andreozzi, F. (2026). Role of automated insulin delivery (AID) systems in glucose control in patients with diabetes mellitus undergoing dialysis in Calabria: AID-DIAL-CAL. Acta Diabetologica, 63(6), 1083-1092. https://doi.org/10.1007/s00592-026-02690-9
Vancouver
Succurro E, Cersosimo G, Sarnelli P, Brisinda F, Gattuso I, Mazza V, et al. Role of automated insulin delivery (AID) systems in glucose control in patients with diabetes mellitus undergoing dialysis in Calabria: AID-DIAL-CAL. Acta Diabetologica. 2026;63(6):1083-1092. doi:10.1007/s00592-026-02690-9
BibTeX
@article{Succurro2026,
author = {Succurro, Elena and Cersosimo, Giuseppe and Sarnelli, Paola and Brisinda, Francesco and Gattuso, Ilaria and Mazza, Valeria and Fabiano, Giuseppe and Iorio, Fiorella and Arena, Roberta and Mazzitello, Giovanni and Nicotera, Ramona and Capria, Maria and Zaza, Gianluigi and Andreucci, Michele and Mancini, Raffaele and Andreozzi, Francesco},
title = {Role of automated insulin delivery (AID) systems in glucose control in patients with diabetes mellitus undergoing dialysis in Calabria: AID-DIAL-CAL},
journal = {Acta Diabetologica},
year = {2026},
volume = {63},
number = {6},
pages = {1083--1092},
doi = {10.1007/s00592-026-02690-9}
}
EUVIMED