EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Effects of external fixator-assisted acute angulation on arterial diameter: a cadaveric model

Akif Mirioglu, Kaan Ali Dalkir, Hakki Can Olke, Bugra Eraslan, Bugra Kundakci, Melih Bagir, Mehmet Ali Deveci

Journal of Orthopaedic Surgery and Research · 2025

DOI: 10.1186/s13018-025-05948-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Surgery and Research, 2025. Verfasst von Akif Mirioglu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Faculty of Medicine, Cukurova University, Adana, Turkey. akifmirioglu@hotmail.com. Hauptthemen laut MEDLINE: External Fixators, Tibia, Femur, Fracture Fixation. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Open fractures with bone and soft tissue loss pose significant challenges in orthopedic surgery. External fixator-assisted techniques, such as acute angulation and shortening, have been proposed to facilitate wound closure. However, the vascular implications of these techniques remain unclear. This cadaveric study aimed to evaluate the effect of acute angulation on arterial narrowing at the proximal tibia and distal femur, identifying angulation thresholds and comparing the vascular tolerance between these anatomical sites. METHODS: Eight lower extremities from four fresh-frozen cadavers were used. Osteotomies were performed at the distal femoral and proximal tibial metaphyses. An Ilizarov circular external fixator provided controlled angulation in varus, valgus, procurvatum, and recurvatum directions. A contrast agent was used for vascular visualization under fluoroscopy. Angulation was gradually increased until arterial narrowing was observed, and the critical angles were recorded. RESULTS: In the proximal tibia, the mean angulation thresholds for arterial narrowing were 45.5° in varus, 26.5° in valgus, 33.8° in procurvatum, and 13.5° in recurvatum. In the distal femur, arterial narrowing occurred at 27° in varus, 32.3° in valgus, 52° in procurvatum, and 22° in recurvatum. Varus angulation was significantly better tolerated at the tibia (p = 0.0286), while procurvatum (p = 0.0294) and recurvatum (p = 0.0286) were better tolerated at the femur. No significant difference was found in valgus angulation (p = 0.559). CONCLUSIONS: The tibia demonstrated higher tolerance for varus angulation, while the femur allowed greater procurvatum and recurvatum before vascular compromise. Recurvatum deformities in the tibia resulted in the earliest arterial narrowing, suggesting a higher risk of vascular complications. These findings provide critical insight for surgeons performing external fixator-assisted soft tissue coverage, helping optimize angulation strategies to prevent vascular complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

External FixatorsTibiaFemurFracture FixationHumansCadaverMaleFemaleAgedMiddle AgedOsteotomyAged, 80 and over

Stichwörter der Autor:innen

External fixatorsFracturesIlizarov techniqueOpenSoft tissue injuriesThrombosis

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Faculty of Medicine, Cukurova University, Adana, Turkey. akifmirioglu@hotmail.com.
  • Department of Orthopaedics and Traumatology, Faculty of Medicine, Cukurova University, Adana, Turkey.
  • Department of Orthopaedics and Traumatology, Baskent University, Adana Turgut Noyan Research and Training Center, Adana, Turkey.
  • Department of Orthopaedics and Traumatology, Koc University, Istanbul, Turkey.

Zitieren

APA

Mirioglu, A., Dalkir, K. A., Olke, H. C., Eraslan, B., Kundakci, B., Bagir, M., & Deveci, M. A. (2025). Effects of external fixator-assisted acute angulation on arterial diameter: a cadaveric model. Journal of Orthopaedic Surgery and Research. https://doi.org/10.1186/s13018-025-05948-0

Vancouver

Mirioglu A, Dalkir KA, Olke HC, Eraslan B, Kundakci B, Bagir M, et al. Effects of external fixator-assisted acute angulation on arterial diameter: a cadaveric model. Journal of Orthopaedic Surgery and Research. 2025. doi:10.1186/s13018-025-05948-0

BibTeX
@article{Mirioglu2025,
  author = {Mirioglu, Akif and Dalkir, Kaan Ali and Olke, Hakki Can and Eraslan, Bugra and Kundakci, Bugra and Bagir, Melih and Deveci, Mehmet Ali},
  title = {Effects of external fixator-assisted acute angulation on arterial diameter: a cadaveric model},
  journal = {Journal of Orthopaedic Surgery and Research},
  year = {2025},
  doi = {10.1186/s13018-025-05948-0}
}
Kostenlos starten →