What causes cup inclination outliers in primary total hip arthroplasty when using a digital inclinometer? A prospective cohort study

Geert Meermans iD, Willem J Van Doorn, Jan-Jaap Kats, Moritz Innmann, George Grammatopoulos iD

HIP International · 2026-11 · 36 (6) · 922-931

DOI: 10.1177/11207000261461259 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift HIP International, online erschienen am 09.08.2026. Verfasst von Geert Meermans und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Bravis Hospital, Roosendaal, The Netherlands. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Acetabulum, Osteoarthritis, Hip. Die Arbeit nennt 61 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

A suboptimal radiographic inclination (RI) angle of the cup has been associated with worse short- and long-term outcomes after primary total hip arthroplasty (THA). There are several factors that lead to RI outliers including cup version, pelvic orientation at time of cup impaction and angle of the cup introducer relative to the floor. The primary aim of this study was to analyse if a digital inclinometer helps achieving a target RI of cups in primary THA and what factors increase the risk of having a cup inclination outside the target zone. Patients and methods: In this prospective study, we included 200 consecutive patients undergoing primary THA. Preoperatively, the surgeon determined the target intraoperative inclination (IOI). The IOI was measured with the aid of a digital inclinometer after seating of the acetabular component. Anteroposterior pelvic radiographs were made to measure the RI of the acetabular component. The target zone for inclination was defined as 35–45° of RI.

Results

The mean RI was 37.9° SD 4.7. There were 53 outliers (26.5%) for the 35–45° zone. The mean absolute ΔIOI cup -IOI target was 1.2° SD 1.0. The absolute ΔIOI cup -IOI target was

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisAcetabulumOsteoarthritis, HipHumansProspective StudiesFemaleMaleAgedMiddle AgedProsthesis DesignRadiographyCohort StudiesRange of Motion, ArticularTreatment Outcome

Stichwörter der Autor:innen

Cupinclinationinclinometerpelvic motionprimary THA

Autor:innen und Institutionen

  • Department of Orthopaedics, Bravis Hospital, Roosendaal, The Netherlands.
  • Department of Orthopaedics and Trauma Surgery, University of Heidelberg, Heidelberg, Germany.
  • Division of Orthopaedic Surgery, The Ottawa Hospital, Critical Care Wing, Ottawa, Ontario, Canada.

ORCID-Profile: Geert Meermans, George Grammatopoulos

Zitieren

APA

Meermans, G., Van Doorn, W. J., Kats, J. J., Innmann, M., & Grammatopoulos, G. (2026). What causes cup inclination outliers in primary total hip arthroplasty when using a digital inclinometer? A prospective cohort study. HIP International, 36(6), 922-931. https://doi.org/10.1177/11207000261461259

Vancouver

Meermans G, Van Doorn WJ, Kats JJ, Innmann M, Grammatopoulos G. What causes cup inclination outliers in primary total hip arthroplasty when using a digital inclinometer? A prospective cohort study. HIP International. 2026;36(6):922-931. doi:10.1177/11207000261461259

BibTeX
@article{Meermans2026,
  author = {Meermans, Geert and Van Doorn, Willem J and Kats, Jan-Jaap and Innmann, Moritz and Grammatopoulos, George},
  title = {What causes cup inclination outliers in primary total hip arthroplasty when using a digital inclinometer? A prospective cohort study},
  journal = {HIP International},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {922--931},
  doi = {10.1177/11207000261461259}
}
Kostenlos starten →