Low avascular necrosis rates in femoral neck fractures: efficacy of cannulated screw fixation
European Journal of Orthopaedic Surgery & Traumatology · 2024
DOI: 10.1007/s00590-024-03956-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2024. Verfasst von S D Scattergood und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Trauma and Orthopaedics, Bristol Royal Infirmary, Bristol, UK. Hauptthemen laut MEDLINE: Femoral Neck Fractures, Bone Screws, Fracture Fixation, Internal, Femur Head Necrosis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Cannulated screw fixation for femoral neck fractures is often limited by concerns of avascular necrosis (AVN) occurring, historically seen in 5–40% of fixed intracapsular fractures. This study aims to assess the outcomes, particularly the AVN rate, associated with current surgical techniques within our unit.
Methods
We conducted a single-center cross-sectional study, manually searching operative records between July 14, 2014, and December 1, 2018, identifying patients with intracapsular fractured neck of femur fixed with cannulated screws, with a minimum of two years follow-up. Patient records and radiographs were reviewed for clinical and radiographic diagnoses of AVN, non-union, post-operative metalwork infection, and screw penetration of the head. Additionally, fracture pattern and displacement, screw configuration, reduction techniques, and adequacy of reduction were recorded, with radiographs independently analyzed by four orthopedic surgeons.
Results
Fifty-six patients were included; average age of 67 years (range 30–100). Forty-two patients (75%) sustained displaced fractures and 14 patients (25%) had undisplaced fractures. Two (4%) patients developed AVN, with no cases of non-union, post-operative metalwork infection or screw penetration of the head. Eight patients (14%) sustained a high-energy injury, though none of these patients developed AVN. All fractures required closed reduction; no open reductions performed. Twenty-seven (64%) of reductions were adequate.
Conclusion
Our observed AVN rate is notably lower than the widely reported figures, even among a significant proportion of displaced fractures that were fixed. This study underscores that with adequate fixation, cannulated screws represent an excellent option for treating intracapsular neck of femur fractures, even in cases of displaced fracture patterns with imperfect reduction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Trauma and Orthopaedics, Bristol Royal Infirmary, Bristol, UK.
- Department of Mathematical Sciences, University of Bath, Bath, UK.
- Department of Trauma and Orthopaedics, Bristol Royal Infirmary, Bristol, UK. jwaf20@bath.ac.uk.
- Department for Health, University of Bath, Bath, UK. jwaf20@bath.ac.uk.
Zitieren
APA
Scattergood, S. D., Berry, A. L., Flannery, O., Burdon, A., Mitchell, S. R., & Fletcher, J. W. A. (2024). Low avascular necrosis rates in femoral neck fractures: efficacy of cannulated screw fixation. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-024-03956-0
Vancouver
Scattergood SD, Berry AL, Flannery O, Burdon A, Mitchell SR, Fletcher JWA. Low avascular necrosis rates in femoral neck fractures: efficacy of cannulated screw fixation. European Journal of Orthopaedic Surgery & Traumatology. 2024. doi:10.1007/s00590-024-03956-0
BibTeX
@article{Scattergood2024,
author = {Scattergood, S D and Berry, A L and Flannery, O and Burdon, A and Mitchell, S R and Fletcher, J W A},
title = {Low avascular necrosis rates in femoral neck fractures: efficacy of cannulated screw fixation},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2024},
doi = {10.1007/s00590-024-03956-0}
}