EUVIMEDEUVIMED entdecken
Crossref

Diagnostic accuracy of various methods for measuring interspinous widening in thoracolumbar posterior ligamentous complex injury shown on MRI

Mohamed M Aly, Meshari M Almutairi, Waleed Almohammadi, Areej Al Fattani, Abdulaziz Alkhoshi, Abdulbaset M Al-Shoaibi

European Spine Journal · 11.07.2026

DOI: 10.1007/s00586-026-10026-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Spine Journal, online erschienen am 11.07.2026. Verfasst von Mohamed M Aly und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Mansoura University, Al Mansurah, Egypt. drmoali26@gmail.com. Die Arbeit nennt 32 Literaturangaben. Gefördert von: The authors declare that this researchResearch center, King Fahd Medical City, Riyadh, Riyadh second cluster.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STUDY DESIGN: retrospective single-center study. PURPOSE: To compare the accuracy of various methods to measure interspinous widening (ISW) on computed tomography (CT) in detecting posterior ligamentous complex (PLC) injuries on magnetic resonance imaging (MRI) for thoracolumbar fractures (TLFs). OVERVIEW OF LITERATURE: ISW showed varying accuracy in detecting PLC injury on MRI due to the lack of standardized methods of measurement. METHODS: We retrospectively reviewed data of 215 consecutive patients with acute TLFs (T1-L2). Three reviewers evaluated MRI and CT images. We measured four ISW parameters: (1) supraspinous distance (SSD): distance between the most posterior aspect of the two spinous processes; (2) midspinous distance (MSD): between the midpoints of the spinous processes; (3) interlaminar distance (ILD): between the most anterior aspect of lamina; and (4) interspinous angle (ISA): the angle between the two spinous processes. For SSD, MSD, and ILD, four different measurements were calculated according to the reference, either the average of upper and lower adjacent levels or whether a ratio or absolute value was used. We compared the diagnostic accuracy of various methods of ISW measurement in detecting black stripe discontinuity on MRI using the area under the receiver operating characteristic curve (AUC) and interobserver reliability using interclass correlation (ICC). RESULTS: All ISW methods showed low accuracy as denoted by AUC < 0.70 (range 0.51-0.65). At the optimum threshold, there was a trend toward higher specificity and lower sensitivity. The ICC was poor for 2 measurements, moderate for 5 measurements, and good for 5 measurements. CONCLUSIONS: This study demonstrates the limited accuracy of ISW methods in detecting PLC injury on MRI. However, ILD showed a trend toward better accuracy; there was no statistically significant difference between all methods. Therefore, ISW, or the lack thereof, especially when isolated, should be interpreted with caution as an indicator for PLC injury.

Schlagwörter

Stichwörter der Autor:innen

AccuracyComputed tomographyInterspinous wideningPosterior ligamentous complexThoracolumbar fractures

Autor:innen und Institutionen

  • Department of Neurosurgery, Mansoura University, Al Mansurah, Egypt. drmoali26@gmail.com.
  • Department of Neurosurgery, Prince Mohammed bin Abdulaziz Hospital, Riyadh, Saudi Arabia. drmoali26@gmail.com.
  • Department of Neurosurgery, Prince Mohammed bin Abdulaziz Hospital, Riyadh, Saudi Arabia.
  • Department of Biostatistics, Epidemiology and Scientific Computing, King Faisal Specialist Hospital & Research Centre, Riyadh, Saudi Arabia.
  • Altakassusi Alliance Medical, Riyadh, Saudi Arabia.

Förderung

  • The authors declare that this researchResearch center, King Fahd Medical City, Riyadh, Riyadh second cluster

Zitieren

APA

Aly, M. M., Almutairi, M. M., Almohammadi, W., Al Fattani, A., Alkhoshi, A., & Al-Shoaibi, A. M. (2026). Diagnostic accuracy of various methods for measuring interspinous widening in thoracolumbar posterior ligamentous complex injury shown on MRI. European Spine Journal. https://doi.org/10.1007/s00586-026-10026-y

Vancouver

Aly MM, Almutairi MM, Almohammadi W, Al Fattani A, Alkhoshi A, Al-Shoaibi AM. Diagnostic accuracy of various methods for measuring interspinous widening in thoracolumbar posterior ligamentous complex injury shown on MRI. European Spine Journal. 2026. doi:10.1007/s00586-026-10026-y

BibTeX
@article{Aly2026,
  author = {Aly, Mohamed M and Almutairi, Meshari M and Almohammadi, Waleed and Al Fattani, Areej and Alkhoshi, Abdulaziz and Al-Shoaibi, Abdulbaset M},
  title = {Diagnostic accuracy of various methods for measuring interspinous widening in thoracolumbar posterior ligamentous complex injury shown on MRI},
  journal = {European Spine Journal},
  year = {2026},
  doi = {10.1007/s00586-026-10026-y}
}
Kostenlos starten →