First experience with a novel image guidance technology for posterior pedicle screw fixation: A cadaveric study on 2D/3D registration-based spine surgery
European Spine Journal · 2026
DOI: 10.1007/s00586-025-09451-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Spine Journal, 2026. Verfasst von Benno Bullert und 6 weiteren Autor:innen. Beteiligte Einrichtung: BG Klinik Ludwigshafen, Ludwigshafen, Germany. Hauptthemen laut MEDLINE: Pedicle Screws, Imaging, Three-Dimensional, Surgery, Computer-Assisted, Spinal Fusion. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Minimally invasive pedicle screw insertion relies on imaging techniques due to limited anatomical visualization. A potential solution for intraoperative 3D guidance is using 2D/3D registration algorithms, which align intraoperative 2D X-rays with preoperatively acquired 3D datasets. This study aimed to evaluate the application of a novel 2D/3D image guidance software in posterior fixation with pedicle screws regarding accuracy, speed, and radiation exposure in a realistic clinical setting.
Methods
Four human cadavers were instrumented with a total of 80 pedicle screws (from T8 to L5) by eight surgeons using 2D/3D image guidance. The surgeons, with varying levels of experience in spine surgery and navigation, utilized the software for the first time. Before the procedures, they underwent a structured one-hour training session. Accuracy, time parameters, and radiation exposure during pedicle screw insertion were assessed.
Results
All K-wires were inserted correctly, demonstrating precise wire placement, regardless of the surgeons’ experience. For pedicle screw placement, the 2D/3D image guidance achieved high accuracy of 95.0%, with no superior or inferior perforations. The mean time for each pedicle screw placement was 7.62 ± 2.83 min, with an average radiation exposure of 1.24 µSv per pedicle screw for the surgeon.
Conclusion
The use of 2D/3D image guidance in this study demonstrated high precision in the placement of K-wires and pedicle screws. Consequently, 2D/3D image guidance presents a promising tool for both experienced and inexperienced users, facilitating precise 3D guidance of pedicle screws with a standard 2D C-arm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- BG Klinik Ludwigshafen, Ludwigshafen, Germany.
- The Robotic Spine Institute, Las Vegas, United States.
- BG Klinik Ludwigshafen, Ludwigshafen, Germany. sven.vetter@bgu-ludwigshafen.de.
Zitieren
APA
Bullert, B., Gierse, J., Mandelka, E., Freischmidt, H., Poelstra, K., Gruetzner, P. A., & Vetter, S. Y. (2026). First experience with a novel image guidance technology for posterior pedicle screw fixation: A cadaveric study on 2D/3D registration-based spine surgery. European Spine Journal. https://doi.org/10.1007/s00586-025-09451-2
Vancouver
Bullert B, Gierse J, Mandelka E, Freischmidt H, Poelstra K, Gruetzner PA, et al. First experience with a novel image guidance technology for posterior pedicle screw fixation: A cadaveric study on 2D/3D registration-based spine surgery. European Spine Journal. 2026. doi:10.1007/s00586-025-09451-2
BibTeX
@article{Bullert2026,
author = {Bullert, Benno and Gierse, Jula and Mandelka, Eric and Freischmidt, Holger and Poelstra, Kornelis and Gruetzner, Paul Alfred and Vetter, Sven Yves},
title = {First experience with a novel image guidance technology for posterior pedicle screw fixation: A cadaveric study on 2D/3D registration-based spine surgery},
journal = {European Spine Journal},
year = {2026},
doi = {10.1007/s00586-025-09451-2}
}
EUVIMED