Factors causing deviation of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis: why does deviation still occur even with robotics?
European Spine Journal · 2025
DOI: 10.1007/s00586-025-08882-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Spine Journal, 2025. Verfasst von Jun Ueno und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, Japan. m0100011@yahoo.co.jp. Hauptthemen laut MEDLINE: Scoliosis, Pedicle Screws, Spinal Fusion, Robotic Surgical Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To clarify the factors that are likely to cause deviation in robot-assisted pedicle screw placement in surgery for adolescent idiopathic scoliosis (AIS). METHODS: Thirty-two consecutive patients with AIS who underwent posterior spinal fusion using a spine robotics system were included. Robot-assisted pedicle screw placements were evaluated using Gertzbein-Robbins system. Deviation rates for breaches of 2 mm or more (Grade C, D, and E) were calculated. Pedicle channel grade, vertebral level, distance from the reference frame (RF), insertion order of the screws, curve laterality, and use of a navigated high-speed drill were investigated as factors causing deviation. RESULTS: A total of 465 robot-assisted pedicle screws were placed, and deviations were observed in 13 (2.8%). The deviation rates were significantly different by pedicle channel grade (Grade 1: 0%, Grade 2: 0%, Grade 3: 3.1%, Grade 4: 20.4%, p < 0.001), vertebral level, and use of a high-speed drill. There were no significant differences in deviation rates for distance from the RF, insertion order of the screws, or curve laterality. Logistic regression analysis showed pedicle channel grade 4 was a significant risk factor for deviation. CONCLUSION: The factor that was most likely to cause deviation in robot-assisted pedicle screw placement in AIS was pedicle channel grade. The most likely situation to cause deviation was a narrow pedicle with an internal diameter of less than one mm. Surgeons should be aware that even with the use of robotics, placing screws into such narrow pedicles is challenging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, Japan. m0100011@yahoo.co.jp.
- Spine Center, St. Marianna University Hospital, Kawasaki, Japan. m0100011@yahoo.co.jp.
- Department of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, Japan.
- Spine Center, St. Marianna University Hospital, Kawasaki, Japan.
- Department of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, Japan. cds00350@par.odn.ne.jp.
- Spine Center, St. Marianna University Hospital, Kawasaki, Japan. cds00350@par.odn.ne.jp.
Zitieren
APA
Ueno, J., Torii, Y., Iinuma, M., Yoshida, A., Tomochika, K., Hideshima, T., Ito, M., & Akazawa, T. (2025). Factors causing deviation of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis: why does deviation still occur even with robotics?. European Spine Journal. https://doi.org/10.1007/s00586-025-08882-1
Vancouver
Ueno J, Torii Y, Iinuma M, Yoshida A, Tomochika K, Hideshima T, et al. Factors causing deviation of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis: why does deviation still occur even with robotics?. European Spine Journal. 2025. doi:10.1007/s00586-025-08882-1
BibTeX
@article{Ueno2025,
author = {Ueno, Jun and Torii, Yoshiaki and Iinuma, Masahiro and Yoshida, Atsuhiro and Tomochika, Ken and Hideshima, Takahiro and Ito, Makoto and Akazawa, Tsutomu},
title = {Factors causing deviation of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis: why does deviation still occur even with robotics?},
journal = {European Spine Journal},
year = {2025},
doi = {10.1007/s00586-025-08882-1}
}
EUVIMED