EUVIMEDEUVIMED entdecken
Crossref

The use of orthogonal plain radiographs in determining the position of thoracic pedicle screws: a cadaveric study

Naresh Kumar, Si Jian Hui, Aye Sander Zaw, Gabriel Zihui Leow, James Thomas Patrick Decourcy Hallinan, K Joshua, Jonathan Jiong Hao Tan, Hee-Kit Wong

European Spine Journal · 2025

DOI: 10.1007/s00586-025-08870-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Spine Journal, 2025. Verfasst von Naresh Kumar und 7 weiteren Autor:innen. Beteiligte Einrichtung: National University Health System, Singapore, Singapore. dosksn@nus.edu.sg. Hauptthemen laut MEDLINE: Thoracic Vertebrae, Pedicle Screws, Spinal Fusion. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Plain radiography remains the standard for intra- and post-operative assessment of pedicle screw placement in spine surgery. While newer technologies like intraoperative CT and navigation have been introduced, they do not consistently improve thoracic pedicle screw accuracy. The aim of this study was to evaluate the accuracy of anteroposterior (AP) alone versus orthogonal (AP and lateral) radiographs in assessing thoracic pedicle screw position across different observer experience levels and to determine the reliability of traditional fluoroscopy as compared to newer modalities. MATERIALS AND METHODS: 23 disarticulated adult thoracic vertebrae were instrumented with pedicle screws placed either intra-osseous or with deliberate medial or lateral cortical violations. True AP and lateral radiographs were independently reviewed by two spine surgeons, two trainees, and two radiologists, blinded to actual screw positions. They categorized screws as "inside pedicle," "out laterally," "out medially," or "unsure." Assessments were compared to confirmed positions using axial views and direct visualization. RESULTS: Orthogonal radiographs had 74.3% accuracy in screw position assessment and 77.3% accuracy in detecting cortical breaches, outperforming AP-only views. Lateral breaches were most easily identified, while intra-osseous placement was most often misclassified. Notably, 20.5% of medial breaches were incorrectly identified as intra-osseous, most commonly by radiologists. Surgeons were more accurate and cautious than both trainees and radiologists in reporting screw placement. CONCLUSION: Orthogonal radiography remains a viable tool for thoracic pedicle screw assessment if used judiciously. Surgical experience enhances interpretation accuracy, particularly in identifying medial breaches, which carry a notable risk of being reported as intra-osseous.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thoracic VertebraePedicle ScrewsSpinal FusionHumansCadaverFluoroscopyMaleFemaleRadiographyAgedMiddle AgedAdultReproducibility of Results

Stichwörter der Autor:innen

AccuracyMedial penetrationOrthogonal radiographsScrew placementThoracic pedicle screws

Autor:innen und Institutionen

  • National University Health System, Singapore, Singapore. dosksn@nus.edu.sg.
  • National University Health System, Singapore, Singapore.

Zitieren

APA

Kumar, N., Hui, S. J., Zaw, A. S., Leow, G. Z., Hallinan, J. T. P. D., Joshua, K., Tan, J. J. H., & Wong, H. K. (2025). The use of orthogonal plain radiographs in determining the position of thoracic pedicle screws: a cadaveric study. European Spine Journal. https://doi.org/10.1007/s00586-025-08870-5

Vancouver

Kumar N, Hui SJ, Zaw AS, Leow GZ, Hallinan JTPD, Joshua K, et al. The use of orthogonal plain radiographs in determining the position of thoracic pedicle screws: a cadaveric study. European Spine Journal. 2025. doi:10.1007/s00586-025-08870-5

BibTeX
@article{Kumar2025,
  author = {Kumar, Naresh and Hui, Si Jian and Zaw, Aye Sander and Leow, Gabriel Zihui and Hallinan, James Thomas Patrick Decourcy and Joshua, K and Tan, Jonathan Jiong Hao and Wong, Hee-Kit},
  title = {The use of orthogonal plain radiographs in determining the position of thoracic pedicle screws: a cadaveric study},
  journal = {European Spine Journal},
  year = {2025},
  doi = {10.1007/s00586-025-08870-5}
}
Kostenlos starten →