Optimal insertion positions of anterior–posterior orientation sacroiliac screw
European Spine Journal · 2023
DOI: 10.1007/s00586-023-07568-w ↗Kurz gefasst
Fachartikel in der Zeitschrift European Spine Journal, 2023. Verfasst von Xiaofei Han und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Wuxi No. 9 People's Hospital Affiliated to Soochow University, No. 999 Liangxi Road, Wuxi, 214062, Jiangsu, China. Hauptthemen laut MEDLINE: Sacrum, Ilium. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Project of Academician Qiu Guixing workstation of Wuxi No.9 People's Hospital, the Top Medical Expert Team of "Taihu Talent Program"in Wuxi, the Top Medical Expert Team of “Taihu Talent Program”in Wuxi.
Abstract (Originalsprache)
PURPOSE: To explore the optimal insertion positions of anterior-posterior orientation sacroiliac screw (AP-SIS). METHODS: Pelvic CT data of 80 healthy adults were employed to measure the anatomical parameters including the insertable ranges of S1 and S2, the length, width and height of the channel with three different horizontal and vertical anterior insertion points starting from the ilium-acetabular recess. To compare pelvic stability by replicating a type C Tile lesions, fifteen synthetic pelvises were fixed with an anterior plate and a posterior AP-SIS employing different anterior insertion points, the whole specimen displacements and shifts in the sacroiliac gap under a cyclic vertical load of 300 N in a biomechanical machine recorded. RESULTS: The posterior and anterior insertable ranges averaged 17.9 × 8.5mm2 and 47.1 × 21.2 mm2, respectively. The channel lengths for three horizontal anterior insertion points gradually decreased from front to back with significant difference (p 0.05). The displacements and shifts for three horizontal insertion points gradually increased from front to back (p 0.05). CONCLUSION: The posterior insertable range is small, where the center between adjacent nerve roots (foramens) is the optimal posterior insertion point. The anterior insertable range is large, where the iliac-acetabular recess is the optimal anterior insertion point for S1 and S2, providing the longest channel and best stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Wuxi No. 9 People's Hospital Affiliated to Soochow University, No. 999 Liangxi Road, Wuxi, 214062, Jiangsu, China.
- Department of Orthopaedics, Wuxi No. 9 People's Hospital Affiliated to Soochow University, No. 999 Liangxi Road, Wuxi, 214062, Jiangsu, China. mayunhongyqd@163.com.
- Department of Orthopaedics, Wuxi No. 9 People's Hospital Affiliated to Soochow University, No. 999 Liangxi Road, Wuxi, 214062, Jiangsu, China. yinqudong@sina.com.cn.
ORCID-Profile: Yunhong Ma, Qudong Yin
Förderung
- Project of Academician Qiu Guixing workstation of Wuxi No.9 People's Hospital
- the Top Medical Expert Team of "Taihu Talent Program"in Wuxi
- the Top Medical Expert Team of “Taihu Talent Program”in Wuxi
Zitieren
APA
Han, X., Cao, Z., Zhao, K., Sun, Z., Ma, Y., & Yin, Q. (2023). Optimal insertion positions of anterior–posterior orientation sacroiliac screw. European Spine Journal. https://doi.org/10.1007/s00586-023-07568-w
Vancouver
Han X, Cao Z, Zhao K, Sun Z, Ma Y, Yin Q. Optimal insertion positions of anterior–posterior orientation sacroiliac screw. European Spine Journal. 2023. doi:10.1007/s00586-023-07568-w
BibTeX
@article{Han2023,
author = {Han, Xiaofei and Cao, Zhihai and Zhao, Kai and Sun, Zhenzhong and Ma, Yunhong and Yin, Qudong},
title = {Optimal insertion positions of anterior–posterior orientation sacroiliac screw},
journal = {European Spine Journal},
year = {2023},
doi = {10.1007/s00586-023-07568-w}
}
EUVIMED