Vergleichsstudie in der Zeitschrift Surgical Endoscopy, 2024. Verfasst von Jessica J Lie und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, University of British Columbia, Vancouver, BC, Canada. Hauptthemen laut MEDLINE: Anastomotic Leak, Surgical Staplers, Elective Surgical Procedures, Surgical Stapling. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The objective of this study was to compare the anastomotic leak rates between powered and manual circular staplers in elective left-sided colorectal resections. METHODS: A retrospective cohort study of elective left-sided colorectal resections before and after implementation of a powered circular stapler at a tertiary care center was conducted. The manual stapler group consisted of consecutive resections performed between January 2016 to December 2016 and the powered stapler group, between September 2021 and December 2022. Primary outcome was 30-day anastomotic leak rate. A chi-squared analysis was performed to compare anastomotic leak rates. Factors associated with anastomotic leak were examined. RESULTS: Two-hundred forty-seven patients were included: 154 in the manual stapler group and 93 in the powered stapler group. Mean (SD) age was 60 (15) years old, 37.7% were female and 72.9% of resections were performed for malignancy. Both groups had similar patient characteristics and surgical technique. Overall leak rate was 2.0% in the manual stapler group and 10.8% in the powered stapler group. The powered staplers were found to have 6.06 times the odds of leak compared to manual staplers (95% CI, 1.62-22.65; p = 0.01). None of the other factors were found to be associated with anastomotic leak. CONCLUSIONS: Patients who had left-sided colorectal anastomosis had higher anastomotic leak rates with powered compared to manual circular staplers. This finding is contrary to previous retrospective studies that found lower leak rates with powered staplers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, University of British Columbia, Vancouver, BC, Canada.
- Division of General Surgery, St Paul's Hospital, Vancouver, BC, Canada.
- Department of Surgery, University of British Columbia, Vancouver, BC, Canada. aghuman@providencehealth.bc.ca.
- Division of General Surgery, St Paul's Hospital, Vancouver, BC, Canada. aghuman@providencehealth.bc.ca.
- Department of Surgery, University of British Columbia, Colorectal Surgeon, St. Paul's Hospital, 1081 Burrard St, Rm C310, Vancouver, BC, V6Z 1Y6, USA. aghuman@providencehealth.bc.ca.
ORCID-Profile: Jessica J Lie, Amandeep Ghuman
Zitieren
APA
Lie, J. J., Samarasinghe, N., Karimuddin, A. A., Brown, C. J., Phang, P. T., Raval, M. J., & Ghuman, A. (2024). Anastomotic leak rate following the implementation of a powered circular stapler in elective colorectal surgeries: a retrospective cohort study. Surgical Endoscopy. https://doi.org/10.1007/s00464-024-11082-5
Vancouver
Lie JJ, Samarasinghe N, Karimuddin AA, Brown CJ, Phang PT, Raval MJ, et al. Anastomotic leak rate following the implementation of a powered circular stapler in elective colorectal surgeries: a retrospective cohort study. Surgical Endoscopy. 2024. doi:10.1007/s00464-024-11082-5
BibTeX
@article{Lie2024,
author = {Lie, Jessica J and Samarasinghe, Nadeesha and Karimuddin, Ahmer A and Brown, Carl J and Phang, P Terry and Raval, Manoj J and Ghuman, Amandeep},
title = {Anastomotic leak rate following the implementation of a powered circular stapler in elective colorectal surgeries: a retrospective cohort study},
journal = {Surgical Endoscopy},
year = {2024},
doi = {10.1007/s00464-024-11082-5}
}
EUVIMED