Comparison of anastomotic stricture rates between 23- and 25-mm powered circular staplers in cervical esophagogastric anastomosis: a propensity-matched study
Esophagus · 2026
DOI: 10.1007/s10388-025-01171-2 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Esophagus, 2026. Verfasst von Akira Saito und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of General and Gastroenterological Surgery, Department of Surgery, Showa University School of Medicine, 1-5-8, Hatanodai, Shinagawa, Tokyo, …. Hauptthemen laut MEDLINE: Esophagectomy, Anastomosis, Surgical, Esophageal Stenosis, Surgical Staplers. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Circular stapler (CS) anastomosis is widely used in McKeown esophagectomy; however, anastomotic stenosis remains a significant concern. This study aimed to compare stenosis rates between newly introduced 23- and 25-mm powered CSs in cervical esophagogastric anastomosis.
Methods
From May 2022 to February 2024, 126 patients who underwent thoracoscopic McKeown esophagectomy with retrosternal gastric conduit reconstruction were retrospectively analyzed. They were categorized into the 23-mm ( n = 52) and 25-mm ( n = 74) CS groups. The primary endpoint was the comparison of anastomotic stricture rates. Propensity score matching was performed to adjust for potential confounders.
Results
After propensity score matching, 39 pairs were selected. The incidence of anastomotic stricture was 18.0% (7 cases) and 12.8% (5 cases) in the 23- and 25-mm CS groups, respectively ( p = not significant [NS]). The incidence of anastomotic leakage and the leakage location revealed no significant differences between the two groups. A two one-sided test for equivalence was performed to compare the risk difference in stricture rates between the groups, resulting in a risk difference of 5.1% with a 90% confidence interval of − 0.087 to 0.191 and a p value of 0.041, suggesting potential equivalence.
Conclusion
In this study, 23- and 25-mm powered CSs achieved comparable anastomotic stricture rates in cervical esophagogastric anastomosis during McKeown esophagectomy. The newly introduced 23-mm powered CS can be a useful option, considering its easier anvil insertion into the residual esophagus when insertion of the 25-mm CS anvil is technically challenging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of General and Gastroenterological Surgery, Department of Surgery, Showa University School of Medicine, 1-5-8, Hatanodai, Shinagawa, Tokyo, 142-8666, Japan. asaito1205@med.showa-u.ac.jp.
- Digestive Diseases Center, Showa University Koto Toyosu Hospital, Tokyo, Japan.
- Division of General and Gastroenterological Surgery, Department of Surgery, Showa University School of Medicine, 1-5-8, Hatanodai, Shinagawa, Tokyo, 142-8666, Japan.
- Esophageal Cancer Center, Showa University Hospital, Tokyo, Japan.
ORCID-Profile: Akira Saito
Zitieren
APA
Saito, A., Otsuka, K., Goto, S., Ariyoshi, T., Yamashita, T., Motegi, K., Komoto, M., Kishimoto, Y., Murakami, M., & Aoki, T. (2026). Comparison of anastomotic stricture rates between 23- and 25-mm powered circular staplers in cervical esophagogastric anastomosis: a propensity-matched study. Esophagus. https://doi.org/10.1007/s10388-025-01171-2
Vancouver
Saito A, Otsuka K, Goto S, Ariyoshi T, Yamashita T, Motegi K, et al. Comparison of anastomotic stricture rates between 23- and 25-mm powered circular staplers in cervical esophagogastric anastomosis: a propensity-matched study. Esophagus. 2026. doi:10.1007/s10388-025-01171-2
BibTeX
@article{Saito2026,
author = {Saito, Akira and Otsuka, Koji and Goto, Satoru and Ariyoshi, Tomotake and Yamashita, Takeshi and Motegi, Kentaro and Komoto, Masahiro and Kishimoto, Yutaka and Murakami, Masahiko and Aoki, Takeshi},
title = {Comparison of anastomotic stricture rates between 23- and 25-mm powered circular staplers in cervical esophagogastric anastomosis: a propensity-matched study},
journal = {Esophagus},
year = {2026},
doi = {10.1007/s10388-025-01171-2}
}
EUVIMED