EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluating the effective segmentation of human lateral geniculate nucleus

Lauren E Welbourne, Joel T Martin, Federico G Segala, Anisa Y Morsi, Daniel H Baker, Alex R Wade

Brain Structure and Function · 25.08.2025 · 230 (7)

DOI: 10.1007/s00429-025-03000-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brain Structure and Function, online erschienen am 25.08.2025. Verfasst von Lauren E Welbourne und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Psychology, University of York, Heslington, York, UK. Hauptthemen laut MEDLINE: Geniculate Bodies, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Biotechnology and Biological Sciences Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Important parts of the visual pathway occur in relatively small subcortical structures that are often difficult to identify and segment using standard structural scans in MRI (e.g. T1 and T2 scans). Studies of the Lateral Geniculate Nucleus (LGN) often use proton density (PD) scan protocols, repeated up to 40 times, then manually segment the LGN structure from the average image. Efficiency is crucial when conducting MRI scans: minimising time spent on structural scanning can increase time available for complementary functional MRI scans and/or reduce scanning costs. In this study we asked how segmentation accuracy depended on the number of PD repeats. Four raters segmented the LGN of five participants, using different numbers of PD scans in the average image (1, 2, 4, 8, 16, 24, 32, 40), and an additional experienced expert rater segmented the LGN for just the 40PD average for all participants. We compared how the rater LGN masks at each scan average level overlapped with the expert masks. One rater performed the segmentation for the 40PD average on four separate days, to measure intra-rater variability across repeats. We also used a state-of-the-art automated segmentation process to compare the reliability to manual segmentation. We found that the average overlap between rater masks and the expert masks increased up to the 16PD scan average level, after which there was no additional benefit to including more PD scans. The automated segmentation masks were comparable to the overlap between the raters (40PD) and expert masks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Geniculate BodiesMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansMaleFemaleAdultReproducibility of ResultsYoung AdultVisual Pathways

Stichwörter der Autor:innen

LGNMRIProton densitySegmentationThalamusVision

Autor:innen und Institutionen

  • Department of Psychology, University of York, Heslington, York, UK.
  • School of Philosophy, Psychology and Language Sciences, University of Edinburgh, Edinburgh, UK.
  • Department of Psychology, University of York, Heslington, York, UK. alex.wade@york.ac.uk.
  • York Biomedical Research Institute, University of York, Heslington, UK. alex.wade@york.ac.uk.

Förderung

  • Biotechnology and Biological Sciences Research Council

Zitieren

APA

Welbourne, L. E., Martin, J. T., Segala, F. G., Morsi, A. Y., Baker, D. H., & Wade, A. R. (2025). Evaluating the effective segmentation of human lateral geniculate nucleus. Brain Structure and Function, 230(7). https://doi.org/10.1007/s00429-025-03000-9

Vancouver

Welbourne LE, Martin JT, Segala FG, Morsi AY, Baker DH, Wade AR. Evaluating the effective segmentation of human lateral geniculate nucleus. Brain Structure and Function. 2025;230(7). doi:10.1007/s00429-025-03000-9

BibTeX
@article{Welbourne2025,
  author = {Welbourne, Lauren E and Martin, Joel T and Segala, Federico G and Morsi, Anisa Y and Baker, Daniel H and Wade, Alex R},
  title = {Evaluating the effective segmentation of human lateral geniculate nucleus},
  journal = {Brain Structure and Function},
  year = {2025},
  volume = {230},
  number = {7},
  doi = {10.1007/s00429-025-03000-9}
}
Kostenlos starten →