EUVIMEDEUVIMED entdecken
Crossref

Indocyanine green dyed gauze-guided minimum invasive surgery for anatomical landmarks and preventing gauze remnants: a pilot study

Yoshihiko Tashiro, Takeshi Aoki, Hidekazu Yasunaga, Shinji Ando

Langenbeck's Archives of Surgery · 2025

DOI: 10.1007/s00423-024-03592-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langenbeck's Archives of Surgery, 2025. Verfasst von Yoshihiko Tashiro und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, 1-5-8 Hatanodai, Shinagawa-ku, Toky…. Hauptthemen laut MEDLINE: Indocyanine Green, Laparoscopy, Anatomic Landmarks, Coloring Agents. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: We aimed to develop a novel fluorescent surgical gauze dyed with indocyanine green (ICG) to guide surgeons to the target anatomical destination during surgery for real-time navigation and to prevent gauze remnants after surgery. METHODS: Surgical gauze was dyed with an aqueous solution of ICG (5.0 × 10- 5 mol L- 1 for Steraze, 1.5 × 10- 4 mol L- 1 for BK-Opeze) at 132 °C (inside pressure: 2.82 atm, 286 kPa) for 15 min using an autoclave, followed by washing with distilled water, drying at room temperature, and sterilizing at 132 °C for 8 min before surgery. Fluorescence (FL) intensity was examined preclinically in the resected specimens using the SPY PHI (Stryker) system. Fourteen patients who underwent laparoscopic- and robotic-assisted gastroenterological surgery at Showa University Hospital were included. RESULTS: Fluorescent emission of ICG-dyed gauze was clearly observed through resected specimens with a thickness of approximately 10 mm or more. In a clinical trial, the ICG-dyed gauze was detected earlier with near-infrared (near-IR) FL imaging than under white light during seven cases of laparoscopic and robotic surgery, which could become a precise marker for surgeons to locate the dissection site despite overlaying tissues and nearby disturbances. Additionally, no seepage of ICG from the gauze was observed in all surgical fields. CONCLUSION: We successfully developed ICG-dyed gauze exhibiting bright near-IR FL which can guide surgeons to the target anatomical destination and prevent gauze remnants during surgery. This invention would be a powerful support for real-time navigation surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Indocyanine GreenLaparoscopyAnatomic LandmarksColoring AgentsRobotic Surgical ProceduresDigestive System Surgical ProceduresMinimally Invasive Surgical ProceduresSurgery, Computer-AssistedHumansPilot ProjectsMaleFemaleMiddle AgedAgedAdult

Stichwörter der Autor:innen

Gauze remnantICG-fluorescent gauzeMinimally invasive surgery; real-time navigation surgerySurgical marker

Substanzen

Indocyanine GreenColoring Agents

Autor:innen und Institutionen

  • Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo, 142-8666, Japan.
  • Division of Gastroenterological and General Surgery, Department of Surgery, School of Medicine, Showa University, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo, 142-8666, Japan. takejp@med.showa-u.ac.jp.
  • Faculty of Fiber Science and Engineering, Kyoto Lnstitute of Technology, Matsugasaki, Sakyo-ku, Kyoto, 606-8585, Japan.
  • Department of Chemical Science & Engineering, School of Materials and Chemical Technology, Institute of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8552, Japan. ando.s.aa@m.titech.ac.jp.

Zitieren

APA

Tashiro, Y., Aoki, T., Yasunaga, H., & Ando, S. (2025). Indocyanine green dyed gauze-guided minimum invasive surgery for anatomical landmarks and preventing gauze remnants: a pilot study. Langenbeck's Archives of Surgery. https://doi.org/10.1007/s00423-024-03592-6

Vancouver

Tashiro Y, Aoki T, Yasunaga H, Ando S. Indocyanine green dyed gauze-guided minimum invasive surgery for anatomical landmarks and preventing gauze remnants: a pilot study. Langenbeck's Archives of Surgery. 2025. doi:10.1007/s00423-024-03592-6

BibTeX
@article{Tashiro2025,
  author = {Tashiro, Yoshihiko and Aoki, Takeshi and Yasunaga, Hidekazu and Ando, Shinji},
  title = {Indocyanine green dyed gauze-guided minimum invasive surgery for anatomical landmarks and preventing gauze remnants: a pilot study},
  journal = {Langenbeck's Archives of Surgery},
  year = {2025},
  doi = {10.1007/s00423-024-03592-6}
}
Kostenlos starten →