Sex differences in beat-to-beat blood pressure variability following isometric handgrip exercise
European Journal of Applied Physiology · 2026
DOI: 10.1007/s00421-025-05988-8 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift European Journal of Applied Physiology, 2026. Verfasst von Rosa V D Guerrero und 5 weiteren Autor:innen. Beteiligte Einrichtung: NeuroV̇ASQ - Integrative Physiology Laboratory, Faculty of Physical Education, University of Brasília, Brasília, DF, Brazil. Hauptthemen laut MEDLINE: Hand Strength, Blood Pressure, Exercise, Isometric Contraction. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Queensland University of Technology - South America Scholarship.
Abstract (Originalsprache)
PURPOSE: Isometric handgrip (IHG) exercise lowers resting blood pressure (BP) and may modulate autonomic control, but its acute effects on beat-to-beat blood pressure variability (BPV) and sex-specific responses are unclear. We examined the impact of a single IHG bout on beat-to-beat BPV in healthy young adults, focusing on sex differences. METHODS: Thirty-eight subjects (20 men, 18 women) completed randomized, sham-controlled crossover trials: true IHG (30% MVC) and sham (3% MVC), each followed by 30 min of seated recovery. Continuous beat-to-beat BP, cardiac output (CO), and total peripheral resistance (TPR) were recorded. Variability was quantified via standard deviation (SD), range, interquartile range (IQR), coefficient of variation (CV), and average real variability (ARV). RESULTS: Beat-to-beat systolic blood pressure (SBP) variability showed marked sex- and time-dependent changes, with no trial-condition effects. In men, SBP SD rose from 6.2 ± 1.4 mmHg at rest to 6.7 ± 2.0 mmHg at 30 min (P 0.05; sex P = 0.018; time P = 0.024). Range and IQR followed SD rising in men at 30 min but stable in women (sex P = 0.022 and P = 0.037). CO ARV increased in men (239 ± 65 to 275 ± 75 mL/min; P 0.05; sex × condition P = 0.026). TPR variability (SD, IQR, CV, ARV) exhibited a significant effect of time (P ≤ 0.002), with no differences between sexes or condition. CONCLUSIONS: A single IHG session does not acutely reduce beat-to-beat BPV in healthy young adults. Nevertheless, clear sex differences in beat-to-beat BPV responses highlight distinct autonomic and vascular regulation mechanisms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- NeuroV̇ASQ - Integrative Physiology Laboratory, Faculty of Physical Education, University of Brasília, Brasília, DF, Brazil.
- Human Integrative Physiology of Exercise (HIPE) Laboratory, Department of Physical Education, Federal University of Paraíba, João Pessoa, PB, Brazil.
- School of Exercise and Nutrition Sciences, Faculty of Health, Queensland University of Technology, Brisbane, QLD, Australia.
- NeuroV̇ASQ - Integrative Physiology Laboratory, Faculty of Physical Education, University of Brasília, Brasília, DF, Brazil. lcvianna@unb.br.
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Queensland University of Technology - South America Scholarship
Zitieren
APA
Guerrero, R. V. D., Teixeira, A. L., Lima, A. S., Lehnen, G. C. S., Bottaro, M., & Vianna, L. C. (2026). Sex differences in beat-to-beat blood pressure variability following isometric handgrip exercise. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-025-05988-8
Vancouver
Guerrero RVD, Teixeira AL, Lima AS, Lehnen GCS, Bottaro M, Vianna LC. Sex differences in beat-to-beat blood pressure variability following isometric handgrip exercise. European Journal of Applied Physiology. 2026. doi:10.1007/s00421-025-05988-8
BibTeX
@article{Guerrero2026,
author = {Guerrero, Rosa V D and Teixeira, André L and Lima, Adamor S and Lehnen, Georgia C S and Bottaro, Martim and Vianna, Lauro C},
title = {Sex differences in beat-to-beat blood pressure variability following isometric handgrip exercise},
journal = {European Journal of Applied Physiology},
year = {2026},
doi = {10.1007/s00421-025-05988-8}
}