Mapping simulated visual field defects with movie-viewing pupil perimetry
Graefe's Archive for Clinical and Experimental Ophthalmology · 2025-06 · 263 (6) · 1641-1650
DOI: 10.1007/s00417-024-06733-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, online erschienen am 09.01.2025. Verfasst von Yuqing Cai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Experimental Psychology, Faculty of Social Sciences, Helmholtz Institute, Utrecht University, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Visual Fields, Visual Field Tests, Pupil, Motion Pictures. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Algemene Nederlandse Vereniging ter voorkoming van Blindheid, Nationaal Regieorgaan Onderwijsonderzoek, China Sponsorship Council.
Abstract (Originalsprache)
Purpose
Assessing the quality of the visual field is important for the diagnosis of ophthalmic and neurological diseases and, consequently, for rehabilitation. Visual field defects (VFDs) are typically assessed using standard automated perimetry (SAP). However, SAP requires participants to understand instructions, maintain fixation and sustained attention, and provide overt responses. These aspects make SAP less suitable for very young or cognitively impaired populations. Here we investigate the feasibility of a new and less demanding form of perimetry. This method assesses visual sensitivity based on pupil responses while performing the perhaps simplest task imaginable: watching movies.
Method
We analyzed an existing dataset, with healthy participants (n = 70) freely watching movies with or without gaze-contingent simulated VFDs, either hemianopia (left- or right-sided) or glaucoma (large nasal arc, small nasal arc, and tunnel vision). Meanwhile, their gaze and pupil size were recorded. Using a recently published toolbox (Open-DPSM), we modeled the relative contribution of visual events to the pupil responses to indicate relative visual sensitivity across the visual field and to dissociate between conditions with and without simulated VFDs.
Result
Conditions with and without simulated VFDs could be dissociated, with an AUC ranging from 0.85 to 0.97, depending on the specific simulated VFD condition. In addition, the dissociation was better when including more movies in the modeling but the model with as few movies as 10 movies was sufficient for a good classification (AUC ranging from 0.84 to 0.96).
Conclusion
Movie-viewing pupil perimetry is promising in providing complementary information for the diagnosis of VFDs, especially for those who are unable to perform conventional perimetry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Experimental Psychology, Faculty of Social Sciences, Helmholtz Institute, Utrecht University, Utrecht, The Netherlands.
- Laboratory for Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
- Experimental Psychology, Faculty of Social Sciences, Helmholtz Institute, Utrecht University, Utrecht, The Netherlands. m.naber@uu.nl.
Förderung
- Algemene Nederlandse Vereniging ter voorkoming van Blindheid
- Nationaal Regieorgaan Onderwijsonderzoek
- China Sponsorship Council
Zitieren
APA
Cai, Y., Strauch, C., Van der Stigchel, S., Brink, A. F. T., Cornelissen, F. W., & Naber, M. (2025). Mapping simulated visual field defects with movie-viewing pupil perimetry. Graefe's Archive for Clinical and Experimental Ophthalmology, 263(6), 1641-1650. https://doi.org/10.1007/s00417-024-06733-1
Vancouver
Cai Y, Strauch C, Van der Stigchel S, Brink AFT, Cornelissen FW, Naber M. Mapping simulated visual field defects with movie-viewing pupil perimetry. Graefe's Archive for Clinical and Experimental Ophthalmology. 2025;263(6):1641-1650. doi:10.1007/s00417-024-06733-1
BibTeX
@article{Cai2025,
author = {Cai, Yuqing and Strauch, Christoph and Van der Stigchel, Stefan and Brink, Antonia F Ten and Cornelissen, Frans W and Naber, Marnix},
title = {Mapping simulated visual field defects with movie-viewing pupil perimetry},
journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
year = {2025},
volume = {263},
number = {6},
pages = {1641--1650},
doi = {10.1007/s00417-024-06733-1}
}