EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Accuracy of intraocular lens power calculation formulae for the Yamane technique of secondary fixation: a systematic review and meta-analysis

Aly Hamza Khowaja, Altamash Shahriyar Ghazanfar, Haroon Tayyab

Graefe's Archive for Clinical and Experimental Ophthalmology · 2024

DOI: 10.1007/s00417-024-06603-w ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, 2024. Verfasst von Aly Hamza Khowaja und 2 weiteren Autor:innen. Beteiligte Einrichtung: Medical College, Aga Khan University, Karachi, 74800, Pakistan. Hauptthemen laut MEDLINE: Lenses, Intraocular, Refraction, Ocular, Lens Implantation, Intraocular, Optics and Photonics. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: This systematic review and meta-analysis aims to assess the refractive outcomes of the Yamane technique for intrascleral fixation of intraocular lenses (SF-IOL) and compare the predictive ability of the various intraocular lens power calculation formulae commonly used in conjunction with the technique. METHODS: A literature search was conducted in the Medline, Scopus, and Cochrane Library databases for articles published from January 2014 to May 2023. Studies that met the predetermined inclusion criteria were included and subjected to analysis. The primary outcome evaluated was the refractive predictive error, defined as the difference between predicted refraction and post-operative manifest refraction. RESULTS: Eleven studies met the inclusion criteria, with a cumulative sample size of 615 patients (mean age: 66.6 years). Various IOL formulae were used, with SRK/T being the most frequently adopted formula. The overall mean refractive predictive error for all formulae combined was -0.02 D, which was not statistically significant (p = 0.99). Subgroup analysis for individual formulae also showed no significant difference from predicted error for any formula (p > 0.05). CONCLUSION: The Yamane technique for SF-IOL shows promising refractive outcomes, and the choice of IOL power calculation formula should be tailored based on patient characteristics and surgeon preference. No formula demonstrated superior predictive ability over others. Further research is needed to develop formulae specifically for eyes with secondary aphakia and poor capsular support.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularRefraction, OcularLens Implantation, IntraocularOptics and PhotonicsBiometryVisual AcuityHumansScleraProsthesis Design

Stichwörter der Autor:innen

IOL power calculation formulaeIntraocular lensesIntrascleral fixationPredictive errorRefractive errorYamane technique

Autor:innen und Institutionen

  • Medical College, Aga Khan University, Karachi, 74800, Pakistan.
  • Department of Ophthalmology and Visual Sciences, Aga Khan University Hospital, Karachi, 74800, Pakistan. haroon.tayyab@aku.edu.

Zitieren

APA

Khowaja, A. H., Ghazanfar, A. S., & Tayyab, H. (2024). Accuracy of intraocular lens power calculation formulae for the Yamane technique of secondary fixation: a systematic review and meta-analysis. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-024-06603-w

Vancouver

Khowaja AH, Ghazanfar AS, Tayyab H. Accuracy of intraocular lens power calculation formulae for the Yamane technique of secondary fixation: a systematic review and meta-analysis. Graefe's Archive for Clinical and Experimental Ophthalmology. 2024. doi:10.1007/s00417-024-06603-w

BibTeX
@article{Khowaja2024,
  author = {Khowaja, Aly Hamza and Ghazanfar, Altamash Shahriyar and Tayyab, Haroon},
  title = {Accuracy of intraocular lens power calculation formulae for the Yamane technique of secondary fixation: a systematic review and meta-analysis},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2024},
  doi = {10.1007/s00417-024-06603-w}
}
Kostenlos starten →