EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of Bruch’s membrane opening minimum rim width and retinal nerve fiber layer thickness in glaucoma diagnosis depending on optic disc size

Verena Anna Englmaier, Jens Julian Storp, Martin Dominik Leclaire, Larissa Lahme, Viktoria Constanze Brücher, Julia Biermann, Raphael Diener, Nicole Eter

Graefe's Archive for Clinical and Experimental Ophthalmology · 2024-06 · 262 (6) · 1899-1910

DOI: 10.1007/s00417-024-06375-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, online erschienen am 19.01.2024. Verfasst von Verena Anna Englmaier und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University Medical Center Munster, Albert-Schweitzer-Campus 1, Building D15, 48149, Munster, Germany. verenaanna.englmai…. Hauptthemen laut MEDLINE: Optic Disk, Bruch Membrane, Nerve Fibers, Retinal Ganglion Cells. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Münster.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/aim The aim of this paper is to compare retinal nerve fiber layer thickness (RNFL) and Bruch’s membrane opening-based minimum rim width (BMO-MRW) in terms of their performance in detecting early and moderate/advanced glaucoma using receiver operating characteristics (ROC) analysis and the classification using the 5th percentile as a cut-off.

Methods

One hundred eyes from 100 patients with early glaucoma (mean deviation (MD): < -5.0 dB) and 100 eyes from 100 patients with moderate/advanced glaucoma (MD: > -5.0 dB) were carefully matched to healthy controls based on optic disc size. Then, the dataset was divided, based on the 50th percentile of the measured Bruch’s membrane opening area (BMO-A), into small (BMO-A < 1.95 mm 2 ) and large optic discs (BMO-A > 1.95 mm 2 ). Finally, the discriminative performance of BMO-MRW and RNFL between glaucoma and controls using ROC analysis and the manufacturer’s classification based on the 5th percentile was analyzed.

Results

In discriminating between glaucoma and matched healthy controls, global BMO-MRW and global RNFL thickness had comparable areas under the ROC curve for eyes with early glaucoma and both small BMO-As (ROC ± confidence interval [CI] 0.91 [0.87 to 0.95] and 0.88 [0.83 to 0.93]) and large BMO-As (0.86 [0.82 to 0.92] and 0.84 [0.79 to 0.90]), as well as in moderate/advanced glaucoma with small BMO-As (0.99 [0.98 to 1.00] and 0.97 [0.95 to 1.00]) and large BMO-As (0.94 [0.91 to 0.98] and 0.97 [0.94 to 1.00]). Using the calculated 5th percentile as a threshold value, the sensitivities for the detection of early and moderate/advanced glaucoma were comparable for BMO-MRW and RNFL in eyes with small optic discs (early glaucoma: fifty-two percent and 61%; moderate/advanced glaucoma: ninety-one percent and 92%). In eyes with large optic discs, the sensitivity of BMO-MRW was inferior to that of RNFL for both early (38% versus 51%) and moderate/advanced (80% versus 91%) glaucoma.

Conclusion

Based on an ROC analysis, the discriminative performance of BMO-MRW and RNFL between patients with early and moderate/advanced glaucoma and a healthy control group matched based on optic disc size is comparable in eyes with BMO-As smaller and larger 1.95 mm 2 . Using a classification based on the 5th percentile, as used in clinical practice, RNFL is shown to be superior to BMO-MRW regarding sensitivity in glaucoma detection with large optic discs. This study underscores the importance of RNFL imaging and measurement in the diagnostic evaluation of glaucoma, especially in cases of large optic discs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Optic DiskBruch MembraneNerve FibersRetinal Ganglion CellsROC CurveTomography, Optical CoherenceVisual FieldsIntraocular PressureHumansFemaleMaleMiddle AgedGlaucomaAgedGlaucoma, Open-AngleRetrospective StudiesReproducibility of Results

Stichwörter der Autor:innen

BMO-MRWDiagnosisGlaucomaMacrodiscsMicrodiscsOptic coherence tomographyRNFL

Autor:innen und Institutionen

  • Department of Ophthalmology, University Medical Center Munster, Albert-Schweitzer-Campus 1, Building D15, 48149, Munster, Germany. verenaanna.englmaier@ukmuenster.de.
  • Department of Ophthalmology, University Medical Center Munster, Albert-Schweitzer-Campus 1, Building D15, 48149, Munster, Germany.

Förderung

  • Universitätsklinikum Münster

Zitieren

APA

Englmaier, V. A., Storp, J. J., Leclaire, M. D., Lahme, L., Brücher, V. C., Biermann, J., Diener, R., & Eter, N. (2024). Accuracy of Bruch’s membrane opening minimum rim width and retinal nerve fiber layer thickness in glaucoma diagnosis depending on optic disc size. Graefe's Archive for Clinical and Experimental Ophthalmology, 262(6), 1899-1910. https://doi.org/10.1007/s00417-024-06375-3

Vancouver

Englmaier VA, Storp JJ, Leclaire MD, Lahme L, Brücher VC, Biermann J, et al. Accuracy of Bruch’s membrane opening minimum rim width and retinal nerve fiber layer thickness in glaucoma diagnosis depending on optic disc size. Graefe's Archive for Clinical and Experimental Ophthalmology. 2024;262(6):1899-1910. doi:10.1007/s00417-024-06375-3

BibTeX
@article{Englmaier2024,
  author = {Englmaier, Verena Anna and Storp, Jens Julian and Leclaire, Martin Dominik and Lahme, Larissa and Brücher, Viktoria Constanze and Biermann, Julia and Diener, Raphael and Eter, Nicole},
  title = {Accuracy of Bruch’s membrane opening minimum rim width and retinal nerve fiber layer thickness in glaucoma diagnosis depending on optic disc size},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2024},
  volume = {262},
  number = {6},
  pages = {1899--1910},
  doi = {10.1007/s00417-024-06375-3}
}
Kostenlos starten →