EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

New Threshold for Large Optic Discs in Children Using Bruch's Membrane Opening Area

Julia V Stingl, Cordula Braun, Sara Walter, Jasmin Rezapour, Felix M Wagner, Lucy Shen, Alicja Strzalkowska, Irene Schmidtmann, Alexander K Schuster, Esther M Hoffmann

Translational Vision Science & Technology · 2025

DOI: 10.1167/tvst.14.4.24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2025. Verfasst von Julia V Stingl und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University Medical Center Mainz, Mainz, Germany. Hauptthemen laut MEDLINE: Optic Disk, Bruch Membrane, Retinal Ganglion Cells. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the peripapillary retinal nerve fiber layer (pRNFL) thickness of large optic discs in children (LOD-C) with normal sized optic discs in children (NOD-C) and large optic discs in adults (LOD-A).

Methods

We included 127 eyes per group (n = 381). Optic discs were considered large if the Bruch's membrane opening (BMO) area was ≥2.5 mm2. pRNFL thickness and minimal rim width (BMO-MRW) were compared between the pediatric groups and the large optic disc groups.

Results

The mean global pRNFL thickness (3.5-mm circle) was 100.2 ± 12.1 µm for LOD-C, 95.9 ± 11.7 µm for NOD-C, and 97.7 ± 10.5 µm for LOD-A. It was significantly thicker in LOD-C compared with NOD-C; the difference decreased toward the periphery. The mean global BMO-MRW was 280.0 ± 41.1 µm for LOD-C, 320.7 ± 10.5 µm for NOD-C, and 252.9 ± 45.8 µm for LOD-A. It was significantly thinner in LOD-C compared with NOD-C, and significantly thicker in LOD-C compared with LOD-A. pRNFL and BMO area showed a positive correlation which was higher if BMO area was >2.8 mm2, BMO-MRW and BMO are showed a negative correlation which was higher if BMO area was 2.8 mm2 should be interpreted with caution, because they seem to be strongly influenced by optic disc size. Translational Relevance: The novel thresholds for small and LOD-C will help to account for the effects of disc status on RNFL and MRW. They will furthermore help clinicians to better diagnose children with suspicious discs for glaucoma.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Optic DiskBruch MembraneRetinal Ganglion CellsHumansChildMaleFemaleTomography, Optical CoherenceAdolescentNerve FibersAdultChild, PreschoolMiddle Aged

Autor:innen und Institutionen

  • Department of Ophthalmology, University Medical Center Mainz, Mainz, Germany.
  • Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Institute for Medical Biostatistics, Epidemiology and Informatics, University Medical Center Mainz, Mainz, Germany.

Zitieren

APA

Stingl, J. V., Braun, C., Walter, S., Rezapour, J., Wagner, F. M., Shen, L., Strzalkowska, A., Schmidtmann, I., Schuster, A. K., & Hoffmann, E. M. (2025). New Threshold for Large Optic Discs in Children Using Bruch's Membrane Opening Area. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.14.4.24

Vancouver

Stingl JV, Braun C, Walter S, Rezapour J, Wagner FM, Shen L, et al. New Threshold for Large Optic Discs in Children Using Bruch's Membrane Opening Area. Translational Vision Science & Technology. 2025. doi:10.1167/tvst.14.4.24

BibTeX
@article{Stingl2025,
  author = {Stingl, Julia V and Braun, Cordula and Walter, Sara and Rezapour, Jasmin and Wagner, Felix M and Shen, Lucy and Strzalkowska, Alicja and Schmidtmann, Irene and Schuster, Alexander K and Hoffmann, Esther M},
  title = {New Threshold for Large Optic Discs in Children Using Bruch's Membrane Opening Area},
  journal = {Translational Vision Science & Technology},
  year = {2025},
  doi = {10.1167/tvst.14.4.24}
}
Kostenlos starten →