Effect of early activation and perimodiolar electrodes on cochlear implant impedance
European Archives of Oto-Rhino-Laryngology · 2026
DOI: 10.1007/s00405-025-09816-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, 2026. Verfasst von Fida Almuhawas und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, College of Medicine, King Saud University, Riyadh, Saudi Arabia. fmuhawas@ksu.edu.sa. Hauptthemen laut MEDLINE: Cochlear Implants, Electric Impedance, Cochlear Implantation, Electrodes, Implanted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Cochlear implantation (CI) is a proven treatment for severe-to-profound hearing loss, yet outcomes vary widely due to individual, device, and surgical factors. Intracochlear changes, such as fibrosis and neo-ossification, influence electrode impedance and device performance, potentially affecting speech perception.
Purpose
This study investigates the effects of early activation (EA) versus standard activation on intracochlear impedance telemetry across different electrode types (lateral vs. perimodiolar). It aims to assess whether EA reduces the impedance and improves CI outcomes.
Methods
This study involved 38 participants (54 CI ears) with Cochlear slim-straight or slim perimodiolar electrodes. Impedance telemetry was measured at four key time points, ranging from intra-operative to 12 months post-activation. Mixed-effects regression models evaluated the influence of activation timing and electrode type on impedance levels, with statistical significance determined using Bonferroni-corrected thresholds.
Results
Perimodiolar electrodes demonstrated significantly lower impedances compared to lateral electrodes, particularly in EA cases. EA consistently resulted in reduced impedances across all cochlear regions, with the greatest reductions observed in the apical and middle regions at 3–6 months ( p < 0.0001). By ≥ 1 year, impedance differences between activation modes diminished but remained significant in select regions ( p = 0.012).
Conclusion
EA, particularly with perimodiolar electrodes, optimizes the electrode-tissue interface, reducing impedance and potentially improving CI performance. These findings highlight the clinical benefits of EA in enhancing CI outcomes and support its consideration in routine CI protocols.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, College of Medicine, King Saud University, Riyadh, Saudi Arabia. fmuhawas@ksu.edu.sa.
- King Abdullah Ear Specialist Center (KAESC), King Saud University Medical City, Riyadh, Saudi Arabia. fmuhawas@ksu.edu.sa.
- Cochlear Arabia Regional Head Quarter, Riyadh, Saudi Arabia.
- King Abdullah Ear Specialist Center (KAESC), King Saud University Medical City, Riyadh, Saudi Arabia.
- Department of Otolaryngology-Head and Neck Surgery, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
Zitieren
APA
Almuhawas, F., Alrushaydan, D., Saleh, S., Aljabr, M., Yalcouy, H., Alzahrani, F., Alsanousi, A., & Hagr, A. (2026). Effect of early activation and perimodiolar electrodes on cochlear implant impedance. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-025-09816-9
Vancouver
Almuhawas F, Alrushaydan D, Saleh S, Aljabr M, Yalcouy H, Alzahrani F, et al. Effect of early activation and perimodiolar electrodes on cochlear implant impedance. European Archives of Oto-Rhino-Laryngology. 2026. doi:10.1007/s00405-025-09816-9
BibTeX
@article{Almuhawas2026,
author = {Almuhawas, Fida and Alrushaydan, Dalal and Saleh, Shaza and Aljabr, Mada and Yalcouy, Hassan and Alzahrani, Farid and Alsanousi, Abdulrahman and Hagr, Abdulrahman},
title = {Effect of early activation and perimodiolar electrodes on cochlear implant impedance},
journal = {European Archives of Oto-Rhino-Laryngology},
year = {2026},
doi = {10.1007/s00405-025-09816-9}
}
EUVIMED