EUVIMEDEUVIMED entdecken
Crossref

Development of an extratracheal device for pulmonary function assessment in laryngectomized patients

Carlos Eduardo Molinari Nardi, Mario Augusto Ferrari de Castro, Daniel A Ribeiro, Luiz Paulo Kowalski, Rogério Aparecido Dedivitis

European Archives of Oto-Rhino-Laryngology · 2025

DOI: 10.1007/s00405-025-09415-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, 2025. Verfasst von Carlos Eduardo Molinari Nardi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Head and Neck Surgery, São Paulo Medical School, University of São Paulo, Avenida Conselheiro Nébias, 444, conjunto 1605, Encruzilhada,…. Hauptthemen laut MEDLINE: Spirometry, Laryngectomy, Respiratory Function Tests. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Pulmonary function assessment in laryngectomized patients is challenging due to technical difficulties in performing spirometry. Existing methods have limitations, including potential air leakage and patient discomfort. The purpose of this study was to develop a simple, comfortable extratracheal device for accurate pulmonary function assessment in laryngectomized patients. METHODS: We designed a silicone extratracheal device with a central connector for spirometer attachment and an adhesive layer for secure skin fixation. Ten laryngectomized patients underwent spirometry using the device. Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEV1), and FEV1/FVC ratio were measured and compared to predicted values. RESULTS: The extratracheal device was validated after performing successful spirometric tests in 10 laryngectomized patients, maintaining the necessary air seal to ensure the accuracy of the results, with no air leakage. Pulmonologists evaluating the device found it to be technically adequate for report generation. CONCLUSION: The developed extratracheal device has proven to be reliable and effective for assessing pulmonary function in laryngectomized patients, potentially serving as a valuable tool for regular pulmonary function monitoring in this population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SpirometryLaryngectomyRespiratory Function TestsHumansMaleFemaleMiddle AgedAgedEquipment DesignForced Expiratory VolumeVital CapacityAdult

Stichwörter der Autor:innen

Extratracheal deviceFEV1FVCLaryngectomyPulmonary function testSpirometry

Autor:innen und Institutionen

  • Department of Head and Neck Surgery, São Paulo Medical School, University of São Paulo, Avenida Conselheiro Nébias, 444, conjunto 1605, Encruzilhada, Santos, São Paulo, 11045-000, Brazil. nardi.cem@gmail.com.
  • Department of Head and Neck Surgery, São Paulo Medical School, University of São Paulo, Avenida Conselheiro Nébias, 444, conjunto 1605, Encruzilhada, Santos, São Paulo, 11045-000, Brazil.
  • Department of Biosciences, Federal University of São Paulo, Santos, Brazil.

Zitieren

APA

Nardi, C. E. M., de Castro, M. A. F., Ribeiro, D. A., Kowalski, L. P., & Dedivitis, R. A. (2025). Development of an extratracheal device for pulmonary function assessment in laryngectomized patients. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-025-09415-8

Vancouver

Nardi CEM, de Castro MAF, Ribeiro DA, Kowalski LP, Dedivitis RA. Development of an extratracheal device for pulmonary function assessment in laryngectomized patients. European Archives of Oto-Rhino-Laryngology. 2025. doi:10.1007/s00405-025-09415-8

BibTeX
@article{Nardi2025,
  author = {Nardi, Carlos Eduardo Molinari and de Castro, Mario Augusto Ferrari and Ribeiro, Daniel A and Kowalski, Luiz Paulo and Dedivitis, Rogério Aparecido},
  title = {Development of an extratracheal device for pulmonary function assessment in laryngectomized patients},
  journal = {European Archives of Oto-Rhino-Laryngology},
  year = {2025},
  doi = {10.1007/s00405-025-09415-8}
}
Kostenlos starten →