Is a central cavity necessary for bioactive glass-ceramic spacers in plated ACDF? A retrospective comparison of solid versus cavity designs
Archives of Orthopaedic and Trauma Surgery · 18.06.2026 · 146 (1)
DOI: 10.1007/s00402-026-06389-y ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, online erschienen am 18.06.2026. Verfasst von Tae Hoon Kang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, College of Medicine, Seoul National University, Seoul, Korea, Republic of. Hauptthemen laut MEDLINE: Spinal Fusion, Ceramics, Diskectomy, Cervical Vertebrae. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Seoul National University.
Abstract (Originalsprache)
Purpose
Traditionally, interbody cages feature a central cavity for graft packing. However, for bioactive glass-ceramic (BGS-7) spacers achieving fusion via surface-mediated osseointegration, this cavity may be biologically redundant and structurally disadvantageous. We compared radiological and clinical outcomes of plated anterior cervical discectomy and fusion (ACDF) using BGS-7 spacers with or without a central cavity.
Methods
We retrospectively reviewed patients undergoing plated ACDF using solid non-cavity (17 patients, 24 levels) or central-cavity (17 patients, 33 levels) BGS-7 spacers. Radiographic fusion was evaluated using dynamic interspinous distance (primary, ≤ 2 mm) and segmental angular motion (secondary, ≤ 4°), alongside CT-based osseointegration (direct contact ≥ 50%). Subsidence (≥ 2 mm) and clinical outcomes were evaluated at 12 months.
Results
Both groups demonstrated comparable 12-month clinical improvements ( p > 0.05). Radiographic fusion rates were equivalent between non-cavity and central-cavity groups based on the primary distance (91.7% vs. 84.8%, p = 0.687) and secondary angular criteria (79.2% vs. 63.6%, p = 0.331). The non-cavity group showed a trend toward superior segmental stability, with a smaller dynamic gap distance (0.82 ± 0.64 mm vs. 1.53 ± 1.99 mm, p = 0.064). CT-based fusion perfectly matched (90.5% vs. 90.9%, p = 1.000). Subsidence rates were comparably low (12.5% vs. 12.1%), with no spacer breakage.
Conclusions
In plated ACDF, adding a central cavity to BGS-7 spacers confers no measurable advantage over the solid design. Solid spacers inherently preserve maximum endplate contact area for optimal load-sharing and surface-mediated fusion. Eliminating the cavity and supplemental grafts avoids logical redundancy, donor-site morbidity, and unnecessary healthcare costs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, College of Medicine, Seoul National University, Seoul, Korea, Republic of.
- Department of Orthopedic Surgery, SMG-SNU BRM Medical Center, Seoul, Korea, Republic of.
- Department of Orthopedic Surgery, Daniel Medical Center, Bucheon, Korea, Republic of.
- Department of Orthopedic Surgery, Plus Orthopedic hospital, Incheon, Korea, Republic of.
- Department of Orthopedic surgery, Sungae hospital, Seoul, Korea, Republic of.
- Department of Orthopedic Surgery, College of Medicine, Seoul National University, Seoul, Korea, Republic of. spinelee@snu.ac.kr.
ORCID-Profile: Jae Hyup Lee
Förderung
- Seoul National University
Zitieren
APA
Kang, T. H., Lee, G., Kang, B., Han, J., Cho, M., & Lee, J. H. (2026). Is a central cavity necessary for bioactive glass-ceramic spacers in plated ACDF? A retrospective comparison of solid versus cavity designs. Archives of Orthopaedic and Trauma Surgery, 146(1). https://doi.org/10.1007/s00402-026-06389-y
Vancouver
Kang TH, Lee G, Kang B, Han J, Cho M, Lee JH. Is a central cavity necessary for bioactive glass-ceramic spacers in plated ACDF? A retrospective comparison of solid versus cavity designs. Archives of Orthopaedic and Trauma Surgery. 2026;146(1). doi:10.1007/s00402-026-06389-y
BibTeX
@article{Kang2026,
author = {Kang, Tae Hoon and Lee, Geumho and Kang, Byungjun and Han, Jeongwoon and Cho, Minjoon and Lee, Jae Hyup},
title = {Is a central cavity necessary for bioactive glass-ceramic spacers in plated ACDF? A retrospective comparison of solid versus cavity designs},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2026},
volume = {146},
number = {1},
doi = {10.1007/s00402-026-06389-y}
}
EUVIMED