Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm?
Archives of Orthopaedic and Trauma Surgery · 2026
DOI: 10.1007/s00402-026-06194-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2026. Verfasst von Felix Olk und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery Ex-Director: Univ.-Prof. Dr. med. R. Krauspe, Heinrich Heine University Düsseldorf, Düsseldorf, Germany. felix.olk@…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Hip Joint. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Düsseldorf. Anstalt öffentlichen Rechts.
Abstract (Originalsprache)
INTRODUCTION: Short-stem total hip arthroplasty (THA) has gained popularity due to its bone-preserving properties and improved physiological load transmission to the proximal femur. Despite these advantages, the ability of short-stem implants to reliably restore leg length and offset remains debated. This study evaluates whether a single offset implant is sufficient for accurate anatomical reconstruction or if multiple offset options are necessary. MATERIAL AND METHODS: A total of 148 anteroposterior pelvic radiographs of patients scheduled for short-stem THA were analysed using MediCAD® software. Femoral offset and leg length were measured, and the accuracy of anatomical reconstruction was assessed within a 5-mm target range. Comparisons were made between a single offset (130°) implant and a dual-offset system (130° and 119°) using the McNemar-Bowker test. RESULTS: With a single 130° CCD (Caput-collum-diaphyseal) offset implant, 55.7% (82/148) of cases achieved satisfactory leg length and offset restoration. The use of a dual-offset system improved accuracy to 79.1% (117/148), demonstrating a statistically significant advantage (p < 0.001). DISCUSSION: The study highlights the need for at least two CCD-angle-offset combinations in short-stem THA to address anatomical variability. A dual-offset system enhances accuracy, reduces biomechanical imbalances, and therefore we expect improvements in clinical outcomes, particularly in teaching hospitals where standardization is essential.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery Ex-Director: Univ.-Prof. Dr. med. R. Krauspe, Heinrich Heine University Düsseldorf, Düsseldorf, Germany. felix.olk@hhu.de.
- Department of Trauma Surgery, Orthopaedics and Hand Surgery, Rheinland Klinikum Neuss GmbH, Neuss, Germany. felix.olk@hhu.de.
- Department of Orthopaedic Surgery Ex-Director: Univ.-Prof. Dr. med. R. Krauspe, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
- Department of Orthopaedic Surgery Director: Univ.-Prof. Dr.med. B. Bittersohl Klinikum Bielefeld gem. GmbH, Bielefeld University, Bielefeld, Germany.
- Department of trauma, hand and orthopaedic surgery, Helios Klinikum Erfurt, Erfurt, Germany.
- Department of trauma and orthopaedic surgery, University Hospital Schleswig-Holstein, Lübeck, Germany.
Förderung
- Universitätsklinikum Düsseldorf. Anstalt öffentlichen Rechts
Zitieren
APA
Olk, F., Bittersohl, B., Babisch, J., Mittelstädt, H., Jäger, M., Krauspe, R., & Zilkens, C. (2026). Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm?. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-026-06194-7
Vancouver
Olk F, Bittersohl B, Babisch J, Mittelstädt H, Jäger M, Krauspe R, et al. Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm?. Archives of Orthopaedic and Trauma Surgery. 2026. doi:10.1007/s00402-026-06194-7
BibTeX
@article{Olk2026,
author = {Olk, Felix and Bittersohl, Bernd and Babisch, Jürgen and Mittelstädt, Hagen and Jäger, Marcus and Krauspe, Rüdiger and Zilkens, Christoph},
title = {Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm?},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2026},
doi = {10.1007/s00402-026-06194-7}
}
EUVIMED