Sensitivity, specificity, and predictive values of ultrasound imaging in primary adhesive capsulitis diagnosis
Skeletal Radiology · 2026
DOI: 10.1007/s00256-025-05086-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Skeletal Radiology, 2026. Verfasst von Clara Morandeira und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Division of Musculoskeletal Radiology, Basurto Universitary Hospital, Avenida Montevideo s/n, 48013, Bilbao, Spain. morandei…. Hauptthemen laut MEDLINE: Bursitis, Shoulder Joint. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: Compare the ultrasound findings in primary adhesive capsulitis and a control group to determine the sonographic diagnostic performance. MATERIALS AND METHODS: This retrospective single-center study compared US findings in patients with a clinical and MRI diagnosis of adhesive capsulitis and a control group of consecutive patients. The US findings were as follows: coracohumeral ligament thickening, increased tissue and vascularity of the rotator interval, axillary recess thickening and hypervascularity, and subacromial gliding. Ultrasound findings were evaluated by Student's t-test and Fisher's exact test (p < 0.05). RESULTS: The mean (± SD) thickness of the coracohumeral ligament (2.3 ± 0.6 vs 1.6 ± 0.3; p < 0.001) was significantly greater in the adhesive capsulitis group (n = 61) than in the control group (n = 69). A cut-off value of 1.6 mm (AUC 0.963, 95% CI 0.934-0.992), yielded 90.2% sensitivity and 90.9% specificity. In the rotator interval, the presence of tissue (72.1% vs 11.6%; p < 0.001) and hypervascularity (8.2% vs 0%, p < 0.02) were significantly higher in the adhesive capsulitis group. In the axillary recess, the mean thickness in the axial (4.7 ± 1.3 vs 1.4 ± 0.4; p < 0.001) and longitudinal plane (4.4 ± 1.2 vs 1.4 ± 0.5; p < 0.001) was significantly higher in the adhesive capsulitis group. A cut-off value of 3 mm (AUC 1) obtained 100% sensitivity and specificity. Increased Doppler flow in the axillary recess (9.8% vs 0%, p < 0.009) and limited subacromial gliding (93.4% vs 2.9%; p < 0.001) were also associated with adhesive capsulitis. CONCLUSION: Several ultrasound findings are typical in primary adhesive capsulitis. Therefore, ultrasound can be considered the first diagnostic tool.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Division of Musculoskeletal Radiology, Basurto Universitary Hospital, Avenida Montevideo s/n, 48013, Bilbao, Spain. morandeiraclara@gmail.com.
- Department of Radiology, Division of Musculoskeletal Radiology, Basurto Universitary Hospital, Avenida Montevideo s/n, 48013, Bilbao, Spain.
- Department of Radiology, Donostia Universitary Hospital, Paseo Doctor Begiristain, 20014, San Sebastian, Spain.
Zitieren
APA
Morandeira, C., Diez, F., Ruiz, B., Cardenal, J., Saenz, M., & Del Cura, J. L. (2026). Sensitivity, specificity, and predictive values of ultrasound imaging in primary adhesive capsulitis diagnosis. Skeletal Radiology. https://doi.org/10.1007/s00256-025-05086-y
Vancouver
Morandeira C, Diez F, Ruiz B, Cardenal J, Saenz M, Del Cura JL. Sensitivity, specificity, and predictive values of ultrasound imaging in primary adhesive capsulitis diagnosis. Skeletal Radiology. 2026. doi:10.1007/s00256-025-05086-y
BibTeX
@article{Morandeira2026,
author = {Morandeira, Clara and Diez, Fernando and Ruiz, Berta and Cardenal, Jaime and Saenz, Martin and Del Cura, Jose Luis},
title = {Sensitivity, specificity, and predictive values of ultrasound imaging in primary adhesive capsulitis diagnosis},
journal = {Skeletal Radiology},
year = {2026},
doi = {10.1007/s00256-025-05086-y}
}
EUVIMED