Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2023. Verfasst von Blake J Schultz und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, McGovern Medical School at UTHealth, 6400 Fannin St, Suite 1700, Houston, TX, 77030, USA. blakeschultzmd@gmail.com. Hauptthemen laut MEDLINE: Pelvic Bones, Fractures, Bone. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: The purpose of this study is to (1) describe a pre-operative planning technique using non-reformatted CT images for insertion of multiple transiliac-transsacral (TI-TS) screws at a single sacral level, (2) define the parameters of a sacral osseous fixation pathway (OFP) that will allow for insertion of two TI-TS screws at a single level, and (3) identify the incidence of sacral OFPs large enough for dual-screw insertion in a representative patient population. METHODS: Retrospective review at a level-1 academic trauma center of a cohort of patients with unstable pelvic injuries treated with two TI-TS screws in the same sacral OFP, and a control cohort of patients without pelvic injuries who had CT scans for other reasons. RESULTS: Thirty-nine patients had two TI-TS screws at S1. Eleven patients, all with dysmorphic osteology, had two TI-TS screws at S2. The average pathway size in the sagittal plane at the level the screws were placed was 17.2 mm in S1 vs 14.4 mm in S2 (p = 0.02). Twenty-one patients (42%) had screws that were intraosseous and 29 (58%) had part of a screw that was juxtaforaminal. No screws were extraosseous. The average OFP size of intraosseous screws was 18.1 mm vs. 15.5 mm for juxtaforaminal screws (p = 0.02). Fourteen millimeters was used as a guide for the lower limit of the OFP for safe dual-screw fixation. Overall, 30% of S1 or S2 pathways were ≥ 14 mm in the control group, with 58% of control patients having at least one of the S1 or S2 pathways ≥ 14 mm. CONCLUSIONS: OFPs ≥ 7.5 mm in the axial plane and 14 mm in the sagittal plane on non-reformatted CT images are large enough for dual-screw fixation at a single sacral level. Overall, 30% of S1 and S2 pathways were ≥ 14 mm and 58% of control patients had an available OFP in at least one sacral level.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, McGovern Medical School at UTHealth, 6400 Fannin St, Suite 1700, Houston, TX, 77030, USA. blakeschultzmd@gmail.com.
- Department of Orthopedics, McGovern Medical School at UTHealth, 6400 Fannin St, Suite 1700, Houston, TX, 77030, USA.
- Department of Orthopedics, Carolinas Medical Center, 1025 Morehead Medical Dr, Charlotte, NC, 28204, USA.
Zitieren
APA
Schultz, B. J., Mayer, R. M., Phelps, K. D., Saiz, A. M., Kellam, P. J., Eastman, J. G., Routt, M. L., & Warner, S. J. (2023). Assessment of sacral osseous fixation pathways for same-level dual transiliac–transsacral screw insertion. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-023-04892-0
Vancouver
Schultz BJ, Mayer RM, Phelps KD, Saiz AM, Kellam PJ, Eastman JG, et al. Assessment of sacral osseous fixation pathways for same-level dual transiliac–transsacral screw insertion. Archives of Orthopaedic and Trauma Surgery. 2023. doi:10.1007/s00402-023-04892-0