Comparison of three echo-guidance techniques in percutaneous patent foramen ovale closure for stroke prevention: Conventional transoesophageal, microprobe transoesophageal and intracardiac echocardiography
Archives of Cardiovascular Diseases · 2023
DOI: 10.1016/j.acvd.2023.08.006 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Archives of Cardiovascular Diseases, 2023. Verfasst von Iphigénie Reibel und 12 weiteren Autor:innen. Beteiligte Einrichtung: Institut de Cardiologie, ACTION Study Group, hôpital Pitié-Salpêtrière, AP-HP, Sorbonne université, Inserm UMRS_1166, 47-83, boulevard de l'Hôpital, …. Hauptthemen laut MEDLINE: Foramen Ovale, Patent, Echocardiography, Transesophageal, Cardiac Catheterization, Stroke. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Themen: Schlaganfall
Abstract (Originalsprache)
BACKGROUND: Recent randomized trials have demonstrated a consistent reduction in recurrent stroke after percutaneous transcatheter patent foramen ovale closure versus medical therapy in patients with recent cryptogenic stroke. AIM: To compare the safety and efficacy of intracardiac echocardiography-guided and microprobe transoesophageal echocardiography-guided patent foramen ovale closure under local anaesthesia with transoesophageal echocardiography-guided patent foramen ovale closure under general anaesthesia. METHODS: This prospective observational single-centre study included 194 consecutive patients scheduled for patent foramen ovale closure for secondary prevention of stroke from February 2018 to December 2019. Patients were asked to choose between an intracardiac echocardiography-guided, microprobe transoesophageal echocardiography-guided or transoesophageal echocardiography-guided procedure. The primary endpoint was the rate of successful closure at 6 months, defined as correct positioning of the device without severe shunt on 6-month contrast echocardiography. RESULTS: Successful closure was high and did not differ between groups: 97.8% (95% confidence interval 88.5-99.9%) in the intracardiac echocardiography-guided group versus 96.9% (95% confidence interval 83.8-99.9%) in the microprobe transoesophageal echocardiography-guided group and 99.1% (95% confidence interval 95.3-99.9%) in the transoesophageal echocardiography-guided group (P=0.63). Adverse events related to patent foramen ovale closure were low and did not differ between groups. CONCLUSION: Our preliminary real-world experience suggests good efficacy and safety with intracardiac echocardiography and microprobe transoesophageal echocardiography guidance compared with conventional transoesophageal echocardiography guidance for percutaneous transcatheter patent foramen ovale closure in recurrent stroke prevention.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institut de Cardiologie, ACTION Study Group, hôpital Pitié-Salpêtrière, AP-HP, Sorbonne université, Inserm UMRS_1166, 47-83, boulevard de l'Hôpital, 75013 Paris, France.
- Institut de Cardiologie, ACTION Study Group, hôpital Pitié-Salpêtrière, AP-HP, Sorbonne université, Inserm UMRS_1166, 47-83, boulevard de l'Hôpital, 75013 Paris, France. Electronic address: gilles.montalescot@aphp.fr.
Zitieren
APA
Reibel, I., Hauguel-Moreau, M., Guedeney, P., Hage, G., Hammoudi, N., Duthoit, G., Zeitouni, M., Lattuca, B., Kernéis, M., Collet, J. P., Silvain, J., Montalescot, G., & ACTION Study Group (2023). Comparison of three echo-guidance techniques in percutaneous patent foramen ovale closure for stroke prevention: Conventional transoesophageal, microprobe transoesophageal and intracardiac echocardiography. Archives of Cardiovascular Diseases. https://doi.org/10.1016/j.acvd.2023.08.006
Vancouver
Reibel I, Hauguel-Moreau M, Guedeney P, Hage G, Hammoudi N, Duthoit G, et al. Comparison of three echo-guidance techniques in percutaneous patent foramen ovale closure for stroke prevention: Conventional transoesophageal, microprobe transoesophageal and intracardiac echocardiography. Archives of Cardiovascular Diseases. 2023. doi:10.1016/j.acvd.2023.08.006
BibTeX
@article{Reibel2023,
author = {Reibel, Iphigénie and Hauguel-Moreau, Marie and Guedeney, Paul and Hage, Georges and Hammoudi, Nadjib and Duthoit, Guillaume and Zeitouni, Michel and Lattuca, Benoit and Kernéis, Mathieu and Collet, Jean-Philippe and Silvain, Johanne and Montalescot, Gilles and ACTION Study Group, ACTION Study Group},
title = {Comparison of three echo-guidance techniques in percutaneous patent foramen ovale closure for stroke prevention: Conventional transoesophageal, microprobe transoesophageal and intracardiac echocardiography},
journal = {Archives of Cardiovascular Diseases},
year = {2023},
doi = {10.1016/j.acvd.2023.08.006}
}
EUVIMED