EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Development and validation of a realistic type III esophageal atresia simulator for the training of pediatric surgeons

Javier Arredondo Montero, Blanca Paola Pérez Riveros, Oscar Emilio Bueso Asfura, Nerea Martín-Calvo, Francisco Javier Pueyo, Nicolás López de Aguileta Castaño

Pediatric Surgery International · 09.09.2024 · 40 (1)

DOI: 10.1007/s00383-024-05827-5 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Pediatric Surgery International, online erschienen am 09.09.2024. Verfasst von Javier Arredondo Montero und 5 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric Surgery Department, Complejo Asistencial Universitario de León, c/Altos de Nava s/n, 24008, León, Castilla y León, Spain. jarredondo@saludc…. Hauptthemen laut MEDLINE: Esophageal Atresia, Models, Anatomic. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad de Navarra.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The technical complexity and limited casuistry of neonatal surgical pathology limit the possibilities of developing the necessary technical competencies by specialists in training. Esophageal atresia constitutes the paradigm of this problem. The use of synthetic 3D models for training is a promising line of research, although the literature is limited.

Methods

We conceptualized, designed, and produced an anatomically realistic model for the open correction of type III oesophageal atresia. We validated it with two groups of participants (experts and non-experts) through face, construct, and content-validity questionnaires.

Results

The model was validated by nine experts and nine non-experts. The mean procedure time for the experts and non-experts groups was 34.0 and 38.4 min, respectively. Two non-experts did not complete the procedure at the designed time (45 min). Regarding the face validity questionnaire, the mean rating of the model was 3.2 out of 4. Regarding the construct validity, we found statistically significant differences between groups for the equidistance between sutures, 100% correct in the expert group vs. 42.9% correct in the non-expert group ( p = 0.02), and for the item “Confirms that tracheoesophageal fistula closure is watertight before continuing the procedure”, correctly assessed by 66.7% of the experts vs. by 11.1% of non-experts ( p = 0.05). Concerning content validity, the mean score was 3.3 out of 4 for the experts and 3.4 out of 4 for the non-experts.

Conclusions

The present model is a cost-effective, simple-to-produce, and validated option for training open correction of type III esophageal atresia. However, future studies with larger sample sizes and blinded validators are needed before drawing definitive conclusions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Esophageal AtresiaModels, AnatomicHumansClinical CompetenceSimulation TrainingPediatricsSurveys and QuestionnairesSurgeons

Stichwörter der Autor:innen

3D modelEsophageal atresiaModelPediatric surgerySiliconeSimulationTraining

Autor:innen und Institutionen

  • Pediatric Surgery Department, Complejo Asistencial Universitario de León, c/Altos de Nava s/n, 24008, León, Castilla y León, Spain. jarredondo@saludcastillayleon.es.
  • Department of Preventive Medicine and Public Health, School of Medicine, University of Navarra, c/Irunlarrea 1, 31008, Pamplona, Navarra, Spain. jarredondo@saludcastillayleon.es.
  • Department of Preventive Medicine and Public Health, School of Medicine, University of Navarra, c/Irunlarrea 1, 31008, Pamplona, Navarra, Spain.
  • Department of Preventive Medicine and Public Health, School of Medicine, University of Navarra, c/Irunlarrea 1, 31008, Pamplona, Navarra, Spain. nmartincalvo@unav.es.
  • IdiSNA, Instituto de Investigación Sanitaria de Navarra, Pamplona, Navarra, Spain. nmartincalvo@unav.es.
  • CIBER de Fisiopatología de la Obesidad y la Nutrición, Instituto de Salud Carlos III, Madrid, Spain. nmartincalvo@unav.es.

Förderung

  • Universidad de Navarra

Zitieren

APA

Arredondo Montero, J., Pérez Riveros, B. P., Bueso Asfura, O. E., Martín-Calvo, N., Pueyo, F. J., & López de Aguileta Castaño, N. (2024). Development and validation of a realistic type III esophageal atresia simulator for the training of pediatric surgeons. Pediatric Surgery International, 40(1). https://doi.org/10.1007/s00383-024-05827-5

Vancouver

Arredondo Montero J, Pérez Riveros BP, Bueso Asfura OE, Martín-Calvo N, Pueyo FJ, López de Aguileta Castaño N. Development and validation of a realistic type III esophageal atresia simulator for the training of pediatric surgeons. Pediatric Surgery International. 2024;40(1). doi:10.1007/s00383-024-05827-5

BibTeX
@article{ArredondoMontero2024,
  author = {Arredondo Montero, Javier and Pérez Riveros, Blanca Paola and Bueso Asfura, Oscar Emilio and Martín-Calvo, Nerea and Pueyo, Francisco Javier and López de Aguileta Castaño, Nicolás},
  title = {Development and validation of a realistic type III esophageal atresia simulator for the training of pediatric surgeons},
  journal = {Pediatric Surgery International},
  year = {2024},
  volume = {40},
  number = {1},
  doi = {10.1007/s00383-024-05827-5}
}
Kostenlos starten →