Effectiveness of the repeated 3-time-balloon-inflation method in reducing coronary stent edge dissection
Heart and Vessels · 2025
DOI: 10.1007/s00380-024-02510-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart and Vessels, 2025. Verfasst von Ryosuke Amisaki und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiovascular Medicine and Endocrinology and Metabolism, Faculty of Medicine, Tottori University, 86 Nishicho, Yonago, Japan. ryosuke.am…. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Coronary, Coronary Vessels, Stents, Coronary Artery Disease. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
The optimal procedural protocol for coronary stent deployment remains undetermined. Post-dilation with a high-pressure balloon is often performed to optimize the stent expansion. However, high-pressure dilation also carries the potential risk of coronary artery injury. A previous in vitro study reported that multiple-times balloon inflation at the same pressure resulted in better stent expansion compared to one-time balloon inflation. In our facility, we frequently perform the repeated 3-time-balloon-inflation method, wherein the stent delivery balloon was inflated 3 times at nominal pressure to deploy the stent, to improve stent expansion without high-pressure balloon inflation. Although this method seems effective in avoiding excessive high-pressure dilation, its clinical data are insufficient. In this study, we investigated the clinical outcomes of the repeated 3-time-balloon-inflation method. This retrospective study included 370 patients with 467 stented coronary lesions. These subjects were divided into two groups: one with standard balloon inflation and the other with repeated 3-time balloon inflation, and treatment outcomes were compared. The repeated 3-time-balloon-inflation group had 254 lesions, and the standard-balloon-inflation group had 213 lesions. Stent edge dissection occurred in 6 lesions (2.8%) in the standard-balloon-inflation group, whereas did not occur in the repeated 3-time-balloon-inflation group. A statistically significant difference remained even after propensity score matching (p = 0.040). The final minimum stent area and long-term clinical outcomes were not significantly different between the two groups. The repeated 3-time-balloon-inflation method may reduce stent edge dissection while demonstrating comparable minimal stent area and long-term outcomes to the standard-balloon-inflation method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiovascular Medicine and Endocrinology and Metabolism, Faculty of Medicine, Tottori University, 86 Nishicho, Yonago, Japan. ryosuke.amisaki@gmail.com.
- Division of Cardiovascular Medicine and Endocrinology and Metabolism, Faculty of Medicine, Tottori University, 86 Nishicho, Yonago, Japan.
Zitieren
APA
Amisaki, R., Watanabe, T., Kobara, S., & Yamamoto, K. (2025). Effectiveness of the repeated 3-time-balloon-inflation method in reducing coronary stent edge dissection. Heart and Vessels. https://doi.org/10.1007/s00380-024-02510-6
Vancouver
Amisaki R, Watanabe T, Kobara S, Yamamoto K. Effectiveness of the repeated 3-time-balloon-inflation method in reducing coronary stent edge dissection. Heart and Vessels. 2025. doi:10.1007/s00380-024-02510-6
BibTeX
@article{Amisaki2025,
author = {Amisaki, Ryosuke and Watanabe, Tomomi and Kobara, Satoshi and Yamamoto, Kazuhiro},
title = {Effectiveness of the repeated 3-time-balloon-inflation method in reducing coronary stent edge dissection},
journal = {Heart and Vessels},
year = {2025},
doi = {10.1007/s00380-024-02510-6}
}
EUVIMED