Photon counting detector CT contrast agent-reduced transcatheter aortic valve reconstruction planning: a comparative study
European Radiology · 06.05.2026 · 36 (9) · 7095-7104
DOI: 10.1007/s00330-026-12613-5 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Radiology, online erschienen am 06.05.2026. Verfasst von Yannik C Layer und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany. yannik.layer@ukbonn.de. Hauptthemen laut MEDLINE: Contrast Media, Transcatheter Aortic Valve Replacement, Tomography, X-Ray Computed, Aortic Valve Stenosis. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Continuous efforts are made to reduce contrast media, improving patient safety, reducing environmental risks, and addressing recurring supply shortages. The aim of this study was to evaluate contrast agent-reduced CT protocols for transcatheter aortic valve reconstruction (TAVR) planning in photon counting detector CT (PCDCT). Materials and methods 162 BMI-matched examinations with standard dose contrast media (SCD; 80 mL; Iohexol 300 mg/mL; 81 examinations) and reduced contrast media dose (RCD; 50 mL; 81 examinations) for TAVR planning on a PCDCT were included in this retrospective monocentric study. Virtual monoenergetic reconstructions (VMI) at 70 keV, 60 keV and 50 keV of contrast agent-reduced examinations were compared with polyenergetic images. Quantitatively, regions-of-interest (ROIs) were placed in the abdominal aorta, iliac bifurcation, femoral artery, left ventricle and trapezius muscles. Signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Qualitatively, diagnostic quality and contrast were assessed on a visual grading scale of 1 (non-diagnostic) – 5 (excellent) and contrast agent dose was estimated.
Results
Averaged, SNR and CNR decreased by 8.71% and 16.78%, respectively, on PCDCT with reduced contrast dose (RCD vs. SCD; both p < 0.001). VMI50keV increased SNR by 44.10% ( p < 0.001) and CNR by 52.73% ( p < 0.001) compared with SCD. In the ascending aorta, SNR increased from 19.80 ± 6.24 (SCD) to 35.78 ± 13.20 (RCD VMI50keV ) and CNR from 18.84 ± 7.78 to 29.77 ± 16.70. Median contrast intensity was 5 for SCD, 4 for RCD CR , and 5 for RCD VMI50keV .
Conclusion
The diagnostic efficacy of TAVR planning assessment using PCDCT with minimized contrast agent dosing is preserved, presenting a practical approach to conserve contrast media. Key Points Question The aim of the study was to implement a PCDCT-adapted contrast media dose protocol to reduce contrast agent volume at sufficient diagnostic quality.
Findings
PCDCT enables substantial contrast dose reduction for TAVR planning with maintained diagnostic image quality. Low-keV virtual monoenergetic image reconstructions compensate for the reduced iodine concentration. Clinical relevance The study demonstrates the potential of contrast media reduction of PCD-CT in clinical routine. This can benefit patients with renal impairment, for example, and reduce the negative effects of iodinated contrast media on the environment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany. yannik.layer@ukbonn.de.
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
Zitieren
APA
Layer, Y. C., Isaak, A., Mesropyan, N., Kupczyk, P. A., Kravchenko, D., Voigt, M., Dell, T., Luetkens, J. A., & Kuetting, D. (2026). Photon counting detector CT contrast agent-reduced transcatheter aortic valve reconstruction planning: a comparative study. European Radiology, 36(9), 7095-7104. https://doi.org/10.1007/s00330-026-12613-5
Vancouver
Layer YC, Isaak A, Mesropyan N, Kupczyk PA, Kravchenko D, Voigt M, et al. Photon counting detector CT contrast agent-reduced transcatheter aortic valve reconstruction planning: a comparative study. European Radiology. 2026;36(9):7095-7104. doi:10.1007/s00330-026-12613-5
BibTeX
@article{Layer2026,
author = {Layer, Yannik C and Isaak, Alexander and Mesropyan, Narine and Kupczyk, Patrick A and Kravchenko, Dmitrij and Voigt, Marilia and Dell, Tatjana and Luetkens, Julian A and Kuetting, Daniel},
title = {Photon counting detector CT contrast agent-reduced transcatheter aortic valve reconstruction planning: a comparative study},
journal = {European Radiology},
year = {2026},
volume = {36},
number = {9},
pages = {7095--7104},
doi = {10.1007/s00330-026-12613-5}
}
EUVIMED