EUVIMEDEUVIMED entdecken
Crossref

Reduced contrast dose for CT head studies during COVID-19-related contrast shortage: Lesson from a crisis

Oksana Marushchak, Amy Wei Lin, Yangmei Li, Aditya Bharatha, Suradech Suthiphosuwan, Yingming Amy Chen, Julian Spears, Shobhit Mathur

Journal of Medical Imaging and Radiation Sciences · 2024

DOI: 10.1016/j.jmir.2024.101433 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Imaging and Radiation Sciences, 2024. Verfasst von Oksana Marushchak und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada. Electronic address: oksana.marushchak@mail.utoronto.ca. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Contrast Media, COVID-19. Die Arbeit nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Intravenous contrast injection protocol for certain CT studies at our institution was revised in June 2022 in response to the global shortage of iohexol. This included CT head studies performed for neuro-navigation (contrast dose from 90 mL to 70 mL). The quality of these studies was assessed. METHODS: Consecutive CT scans before (n = 32) and after (n = 32) contrast dose reduction were reviewed. Demographic data was obtained from the chart. Subjective observations made by two radiologists in consensus included overall study quality (Likert scale of 1 to 5) and lesion location, margins and internal characteristics that were compared with MRI findings (reference standard) using Fisher's exact test. Superior sagittal sinus attenuation, used as an objective measurement of enhancement, and lesion size were compared using Student's t-test. The institutional database was searched for any study requiring repetition or deemed non-diagnostic. RESULTS/DISCUSSION: The average age (61.1 ± 12.7 years and 61.6 ± 14.9 years) and body surface area (BSA) (1.9 ± 0.3 m2 and 1.9 ± 0.02 m2) was not significantly different (p > 0.05) between groups. There was no significant difference (p > 0.05) in objective or subjective enhancement between the two groups. There was no significant difference between CT and MRI for lesion size, location, number, margins and internal enhancement characteristics in the two groups. No study required repetition or was reported as non-diagnostic. There was no adverse comment about study quality in operative notes. CONCLUSION: Reduced contrast dose neuro-navigation CT head studies are not different in quality compared to the conventional studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedContrast MediaCOVID-19HumansMiddle AgedMaleFemaleAgedHeadIohexolSARS-CoV-2Retrospective StudiesRadiation DosageMagnetic Resonance Imaging

Stichwörter der Autor:innen

COVID-19CT headContrast doseContrast shortageIodinated contrast media shortageQuality assurance

Substanzen

Contrast MediaIohexol

Autor:innen und Institutionen

  • Department of Medical Imaging, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada. Electronic address: oksana.marushchak@mail.utoronto.ca.
  • Department of Medical Imaging, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada.
  • Department of Medical Imaging, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Canada; Li Ka Shing Knowledge Institute, Toronto, Canada.
  • Division of Neurosurgery, Department of Surgery, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Canada.

Zitieren

APA

Marushchak, O., Lin, A. W., Li, Y., Bharatha, A., Suthiphosuwan, S., Chen, Y. A., Spears, J., & Mathur, S. (2024). Reduced contrast dose for CT head studies during COVID-19-related contrast shortage: Lesson from a crisis. Journal of Medical Imaging and Radiation Sciences. https://doi.org/10.1016/j.jmir.2024.101433

Vancouver

Marushchak O, Lin AW, Li Y, Bharatha A, Suthiphosuwan S, Chen YA, et al. Reduced contrast dose for CT head studies during COVID-19-related contrast shortage: Lesson from a crisis. Journal of Medical Imaging and Radiation Sciences. 2024. doi:10.1016/j.jmir.2024.101433

BibTeX
@article{Marushchak2024,
  author = {Marushchak, Oksana and Lin, Amy Wei and Li, Yangmei and Bharatha, Aditya and Suthiphosuwan, Suradech and Chen, Yingming Amy and Spears, Julian and Mathur, Shobhit},
  title = {Reduced contrast dose for CT head studies during COVID-19-related contrast shortage: Lesson from a crisis},
  journal = {Journal of Medical Imaging and Radiation Sciences},
  year = {2024},
  doi = {10.1016/j.jmir.2024.101433}
}
Kostenlos starten →