Reduced contrast dose for CT head studies during COVID-19-related contrast shortage: Lesson from a crisis
Journal of Medical Imaging and Radiation Sciences · 2024
DOI: 10.1016/j.jmir.2024.101433 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Imaging and Radiation Sciences, 2024. Verfasst von Oksana Marushchak und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada. Electronic address: oksana.marushchak@mail.utoronto.ca. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Contrast Media, COVID-19. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: Intravenous contrast injection protocol for certain CT studies at our institution was revised in June 2022 in response to the global shortage of iohexol. This included CT head studies performed for neuro-navigation (contrast dose from 90 mL to 70 mL). The quality of these studies was assessed. METHODS: Consecutive CT scans before (n = 32) and after (n = 32) contrast dose reduction were reviewed. Demographic data was obtained from the chart. Subjective observations made by two radiologists in consensus included overall study quality (Likert scale of 1 to 5) and lesion location, margins and internal characteristics that were compared with MRI findings (reference standard) using Fisher's exact test. Superior sagittal sinus attenuation, used as an objective measurement of enhancement, and lesion size were compared using Student's t-test. The institutional database was searched for any study requiring repetition or deemed non-diagnostic. RESULTS/DISCUSSION: The average age (61.1 ± 12.7 years and 61.6 ± 14.9 years) and body surface area (BSA) (1.9 ± 0.3 m2 and 1.9 ± 0.02 m2) was not significantly different (p > 0.05) between groups. There was no significant difference (p > 0.05) in objective or subjective enhancement between the two groups. There was no significant difference between CT and MRI for lesion size, location, number, margins and internal enhancement characteristics in the two groups. No study required repetition or was reported as non-diagnostic. There was no adverse comment about study quality in operative notes. CONCLUSION: Reduced contrast dose neuro-navigation CT head studies are not different in quality compared to the conventional studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Imaging, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada. Electronic address: oksana.marushchak@mail.utoronto.ca.
- Department of Medical Imaging, St. Michael's Hospital, Unity Health Toronto, Toronto, Canada.
- Department of Medical Imaging, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Canada; Li Ka Shing Knowledge Institute, Toronto, Canada.
- Division of Neurosurgery, Department of Surgery, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Canada.
Zitieren
APA
Marushchak, O., Lin, A. W., Li, Y., Bharatha, A., Suthiphosuwan, S., Chen, Y. A., Spears, J., & Mathur, S. (2024). Reduced contrast dose for CT head studies during COVID-19-related contrast shortage: Lesson from a crisis. Journal of Medical Imaging and Radiation Sciences. https://doi.org/10.1016/j.jmir.2024.101433
Vancouver
Marushchak O, Lin AW, Li Y, Bharatha A, Suthiphosuwan S, Chen YA, et al. Reduced contrast dose for CT head studies during COVID-19-related contrast shortage: Lesson from a crisis. Journal of Medical Imaging and Radiation Sciences. 2024. doi:10.1016/j.jmir.2024.101433
BibTeX
@article{Marushchak2024,
author = {Marushchak, Oksana and Lin, Amy Wei and Li, Yangmei and Bharatha, Aditya and Suthiphosuwan, Suradech and Chen, Yingming Amy and Spears, Julian and Mathur, Shobhit},
title = {Reduced contrast dose for CT head studies during COVID-19-related contrast shortage: Lesson from a crisis},
journal = {Journal of Medical Imaging and Radiation Sciences},
year = {2024},
doi = {10.1016/j.jmir.2024.101433}
}