High-resolution deep learning reconstruction for coronary CTA: compared efficacy of stenosis evaluation with other methods at in vitro and in vivo studies
European Radiology · 2025
DOI: 10.1007/s00330-025-11376-9 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Radiology, 2025. Verfasst von Takahiro Matsuyama und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan. Hauptthemen laut MEDLINE: Deep Learning, Coronary Stenosis, Computed Tomography Angiography, Coronary Angiography. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Canon Medical Systems Corporation.
Abstract (Originalsprache)
OBJECTIVE: To directly compare coronary arterial stenosis evaluations by hybrid-type iterative reconstruction (IR), model-based IR (MBIR), deep learning reconstruction (DLR), and high-resolution deep learning reconstruction (HR-DLR) on coronary computed tomography angiography (CCTA) in both in vitro and in vivo studies. MATERIALS AND METHODS: For the in vitro study, a total of three-vessel tube phantoms with diameters of 3 mm, 4 mm, and 5 mm and with simulated non-calcified stepped stenosis plaques with degrees of 0%, 25%, 50%, and 75% stenosis were scanned with area-detector CT (ADCT) and ultra-high-resolution CT (UHR-CT). Then, ADCT data were reconstructed using all methods, although UHR-CT data were reconstructed with hybrid-type IR, MBIR, and DLR. For the in vivo study, patients who had undergone CCTA at ADCT were retrospectively selected, and each CCTA data set was reconstructed with all methods. To compare the image noise and measurement accuracy at each of the stenosis levels, image noise, and inner diameter were evaluated and statistically compared. To determine the effect of HR-DLR on CAD-RADS evaluation accuracy, the accuracy of CAD-RADS categorization of all CCTAs was compared by using McNemar's test. RESULTS: The image noise of HR-DLR was significantly lower than that of others on ADCT and UHR-CT (p < 0.0001). At a 50% and 75% stenosis level for each phantom, hybrid-type IR showed a significantly larger mean difference on ADCT than did others (p < 0.05). At in vivo study, 31 patients were included. Accuracy on HR-DLR was significantly higher than that on hybrid-type IR, MBIR, or DLR (p < 0.0001). CONCLUSION: HR-DLR is potentially superior for coronary arterial stenosis evaluations to hybrid-type IR, MBIR, or DLR shown on CCTA. KEY POINTS: Question How do coronary arterial stenosis evaluations by hybrid-type IR, MBIR, DLR, and HR-DLR compare to coronary CT angiography? Findings HR-DLR showed significantly lower image noise and more accurate coronary artery disease reporting and data system (CAD-RADS) evaluation than others. Clinical relevance HR-DLR is potentially superior to other reconstruction methods for coronary arterial stenosis evaluations, as demonstrated by coronary CT angiography results on ADCT and as shown in both in vitro and in vivo studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan.
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan.
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan.
- Canon Medical Systems Corporation, Otawara, Japan.
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Japan.
- Department of Cardiology, Fujita Health University School of Medicine, Toyoake, Japan.
Förderung
- Canon Medical Systems Corporation
Zitieren
APA
Matsuyama, T., Nagata, H., Ozawa, Y., Ito, Y., Kimata, H., Fujii, K., Akino, N., Ueda, T., Nomura, M., Yoshikawa, T., Takenaka, D., Kawai, H., Sarai, M., Izawa, H., & Ohno, Y. (2025). High-resolution deep learning reconstruction for coronary CTA: compared efficacy of stenosis evaluation with other methods at in vitro and in vivo studies. European Radiology. https://doi.org/10.1007/s00330-025-11376-9
Vancouver
Matsuyama T, Nagata H, Ozawa Y, Ito Y, Kimata H, Fujii K, et al. High-resolution deep learning reconstruction for coronary CTA: compared efficacy of stenosis evaluation with other methods at in vitro and in vivo studies. European Radiology. 2025. doi:10.1007/s00330-025-11376-9
BibTeX
@article{Matsuyama2025,
author = {Matsuyama, Takahiro and Nagata, Hiroyuki and Ozawa, Yoshiyuki and Ito, Yuya and Kimata, Hirona and Fujii, Kenji and Akino, Naruomi and Ueda, Takahiro and Nomura, Masahiko and Yoshikawa, Takeshi and Takenaka, Daisuke and Kawai, Hideki and Sarai, Masayoshi and Izawa, Hideo and Ohno, Yoshiharu},
title = {High-resolution deep learning reconstruction for coronary CTA: compared efficacy of stenosis evaluation with other methods at in vitro and in vivo studies},
journal = {European Radiology},
year = {2025},
doi = {10.1007/s00330-025-11376-9}
}
EUVIMED