EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing the stability of photon-counting CT: insights from a 2-year longitudinal study

Leening P Liu, Pouyan Pasyar, Fang Liu, Quy Cao, Olivia F Sandvold, Martin V Rybertt, Pooyan Sahbaee, Russell T Shinohara, Harold I Litt, Peter B Noël

European Radiology · 19.12.2024 · 35 (7) · 3721-3728

DOI: 10.1007/s00330-024-11244-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, online erschienen am 19.12.2024. Verfasst von Leening P Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA. leening.liu@pennmedicine.upenn.edu. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering, Siemens Medical Solutions USA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Among the advancements in computed tomography (CT) technology, photon-counting computed tomography (PCCT) stands out as a significant innovation, providing superior spectral imaging capabilities while simultaneously reducing radiation exposure. Its long-term stability is important for clinical care, especially longitudinal studies, but is currently unknown. This study sets out to comprehensively analyze the long-term stability of a first-generation clinical PCCT scanner.

Methods

Over a 2-year period, from November 2021 to November 2023, we conducted weekly identical experiments utilizing the same multi-energy CT protocol. Throughout this period, notable software and hardware modifications were meticulously recorded. Various tissue-mimicking inserts were scanned weekly to rigorously assess the stability of Hounsfield Units (HU) and image noise in Virtual Monochromatic Images (VMIs) and iodine density maps.

Results

Spectral results consistently demonstrated the quantitative stability of PCCT. VMIs exhibited stable HU values, such as variation in relative error for VMI 70 keV measuring 0.11% and 0.30% for single-source and dual-source modes, respectively. Similarly, noise levels remained stable with slight fluctuations linked to software changes for VMI 40 and 70 keV that corresponded to changes of 8 and 1 HU, respectively. Furthermore, iodine density quantification maintained stability and showed significant improvement with software and hardware changes, especially in dual-source mode with nominal errors decreasing from 1.44 to 0.03 mg/mL.

Conclusion

This study provides the first long-term reproducibility assessment of quantitative PCCT imaging, highlighting its potential for the clinical arena. Key Points Question Photon-counting CT (PCCT) provides critical spectral imaging for improved diagnostic accuracy, but its long-term quantitative stability over time is still unknown.

Findings

The clinical PCCT system demonstrated stable Hounsfield Units (HU) and image noise over 2 years, ensuring reliable quantitative imaging and improving diagnostic accuracy. Clinical relevance This study showcased the exceptional value of PCCT in diagnostic radiology, particularly for its application in longitudinal studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedLongitudinal StudiesPhotonsHumansPhantoms, ImagingSoftware

Stichwörter der Autor:innen

CTPhoton-counting CTQuantitative stabilitySpectral CT

Autor:innen und Institutionen

  • Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA. leening.liu@pennmedicine.upenn.edu.
  • Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA. leening.liu@pennmedicine.upenn.edu.
  • Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA.
  • Penn Statistics in Imaging and Visualization Center, Department of Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Philadelphia, PA, USA.
  • Center for Biomedical Imaging Computing and Analytics, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering
  • Siemens Medical Solutions USA

Zitieren

APA

Liu, L. P., Pasyar, P., Liu, F., Cao, Q., Sandvold, O. F., Rybertt, M. V., Sahbaee, P., Shinohara, R. T., Litt, H. I., & Noël, P. B. (2024). Assessing the stability of photon-counting CT: insights from a 2-year longitudinal study. European Radiology, 35(7), 3721-3728. https://doi.org/10.1007/s00330-024-11244-y

Vancouver

Liu LP, Pasyar P, Liu F, Cao Q, Sandvold OF, Rybertt MV, et al. Assessing the stability of photon-counting CT: insights from a 2-year longitudinal study. European Radiology. 2024;35(7):3721-3728. doi:10.1007/s00330-024-11244-y

BibTeX
@article{Liu2024,
  author = {Liu, Leening P and Pasyar, Pouyan and Liu, Fang and Cao, Quy and Sandvold, Olivia F and Rybertt, Martin V and Sahbaee, Pooyan and Shinohara, Russell T and Litt, Harold I and Noël, Peter B},
  title = {Assessing the stability of photon-counting CT: insights from a 2-year longitudinal study},
  journal = {European Radiology},
  year = {2024},
  volume = {35},
  number = {7},
  pages = {3721--3728},
  doi = {10.1007/s00330-024-11244-y}
}
Kostenlos starten →