Multi-reader multiparametric DECT study evaluating different strengths of iterative and deep learning-based image reconstruction techniques
European Radiology · 2024
DOI: 10.1007/s00330-024-10974-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, 2024. Verfasst von Jinjin Cao und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA. Hauptthemen laut MEDLINE: Deep Learning, Tomography, X-Ray Computed, Radiographic Image Interpretation, Computer-Assisted, Radiography, Dual-Energy Scanned Projection. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: To perform a multi-reader comparison of multiparametric dual-energy computed tomography (DECT) images reconstructed with deep-learning image reconstruction (DLIR) and standard-of-care adaptive statistical iterative reconstruction-V (ASIR-V). METHODS: This retrospective study included 100 patients undergoing portal venous phase abdominal CT on a rapid kVp switching DECT scanner. Six reconstructed DECT sets (ASIR-V and DLIR, each at three strengths) were generated. Each DECT set included 65 keV monoenergetic, iodine, and virtual unenhanced (VUE) images. Using a Likert scale, three radiologists performed qualitative assessments for image noise, contrast, small structure visibility, sharpness, artifact, and image preference. Quantitative assessment was performed by measuring attenuation, image noise, and contrast-to-noise ratios (CNR). For the qualitative analysis, Gwet's AC2 estimates were used to assess agreement. RESULTS: DECT images reconstructed with DLIR yielded better qualitative scores than ASIR-V images except for artifacts, where both groups were comparable. DLIR-H images were rated higher than other reconstructions on all parameters (p-value < 0.05). On quantitative analysis, there was no significant difference in the attenuation values between ASIR-V and DLIR groups. DLIR images had higher CNR values for the liver and portal vein, and lower image noise, compared to ASIR-V images (p-value < 0.05). The subgroup analysis of patients with large body habitus (weight ≥ 90 kg) showed similar results to the study population. Inter-reader agreement was good-to-very good overall. CONCLUSION: Multiparametric post-processed DECT datasets reconstructed with DLIR were preferred over ASIR-V images with DLIR-H yielding the highest image quality scores. CLINICAL RELEVANCE STATEMENT: Deep-learning image reconstruction in dual-energy CT demonstrated significant benefits in qualitative and quantitative image metrics compared to adaptive statistical iterative reconstruction-V. KEY POINTS: Dual-energy CT (DECT) images reconstructed using deep-learning image reconstruction (DLIR) showed superior qualitative scores compared to adaptive statistical iterative reconstruction-V (ASIR-V) reconstructed images, except for artifacts where both reconstructions were rated comparable. While there was no significant difference in attenuation values between ASIR-V and DLIR groups, DLIR images showed higher contrast-to-noise ratios (CNR) for liver and portal vein, and lower image noise (p value < 0.05). Subgroup analysis of patients with large body habitus (weight ≥ 90 kg) yielded similar findings to the overall study population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA.
- Institute for Diagnostic and Interventional Radiology, University Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
- Department of Radiology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand.
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA, 02114-2696, USA. akambadakone@mgh.harvard.edu.
Zitieren
APA
Cao, J., Mroueh, N., Lennartz, S., Mercaldo, N. D., Pisuchpen, N., Kongboonvijit, S., Srinivas Rao, S., Yuenyongsinchai, K., Pierce, T. T., Sertic, M., Chung, R., & Kambadakone, A. R. (2024). Multi-reader multiparametric DECT study evaluating different strengths of iterative and deep learning-based image reconstruction techniques. European Radiology. https://doi.org/10.1007/s00330-024-10974-3
Vancouver
Cao J, Mroueh N, Lennartz S, Mercaldo ND, Pisuchpen N, Kongboonvijit S, et al. Multi-reader multiparametric DECT study evaluating different strengths of iterative and deep learning-based image reconstruction techniques. European Radiology. 2024. doi:10.1007/s00330-024-10974-3
BibTeX
@article{Cao2024,
author = {Cao, Jinjin and Mroueh, Nayla and Lennartz, Simon and Mercaldo, Nathaniel D and Pisuchpen, Nisanard and Kongboonvijit, Sasiprang and Srinivas Rao, Shravya and Yuenyongsinchai, Kampon and Pierce, Theodore T and Sertic, Madeleine and Chung, Ryan and Kambadakone, Avinash R},
title = {Multi-reader multiparametric DECT study evaluating different strengths of iterative and deep learning-based image reconstruction techniques},
journal = {European Radiology},
year = {2024},
doi = {10.1007/s00330-024-10974-3}
}
EUVIMED