EUVIMEDEUVIMED entdecken
Crossref

Learning CT-free attenuation-corrected total-body PET images through deep learning

Wenbo Li, Zhenxing Huang, Zixiang Chen, Yongluo Jiang, Chao Zhou, Xu Zhang, Wei Fan, Yumo Zhao, Lulu Zhang, Liwen Wan, Yongfeng Yang, Hairong Zheng und 2 weitere

European Radiology · 2024

DOI: 10.1007/s00330-024-10647-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, 2024. Verfasst von Wenbo Li und 13 weiteren Autor:innen. Beteiligte Einrichtung: Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China. Hauptthemen laut MEDLINE: Deep Learning, Whole Body Imaging, Positron Emission Tomography Computed Tomography. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shenzhen Excellent Technological Innovation Talent Training Project of China, Shenzhen Science and Technology Innovation Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Total-body PET/CT scanners with long axial fields of view have enabled unprecedented image quality and quantitative accuracy. However, the ionizing radiation from CT is a major issue in PET imaging, which is more evident with reduced radiopharmaceutical doses in total-body PET/CT. Therefore, we attempted to generate CT-free attenuation-corrected (CTF-AC) total-body PET images through deep learning. METHODS: Based on total-body PET data from 122 subjects (29 females and 93 males), a well-established cycle-consistent generative adversarial network (Cycle-GAN) was employed to generate CTF-AC total-body PET images directly while introducing site structures as prior information. Statistical analyses, including Pearson correlation coefficient (PCC) and t-tests, were utilized for the correlation measurements. RESULTS: The generated CTF-AC total-body PET images closely resembled real AC PET images, showing reduced noise and good contrast in different tissue structures. The obtained peak signal-to-noise ratio and structural similarity index measure values were 36.92 ± 5.49 dB (p < 0.01) and 0.980 ± 0.041 (p < 0.01), respectively. Furthermore, the standardized uptake value (SUV) distribution was consistent with that of real AC PET images. CONCLUSION: Our approach could directly generate CTF-AC total-body PET images, greatly reducing the radiation risk to patients from redundant anatomical examinations. Moreover, the model was validated based on a multidose-level NAC-AC PET dataset, demonstrating the potential of our method for low-dose PET attenuation correction. In future work, we will attempt to validate the proposed method with total-body PET/CT systems in more clinical practices. CLINICAL RELEVANCE STATEMENT: The ionizing radiation from CT is a major issue in PET imaging, which is more evident with reduced radiopharmaceutical doses in total-body PET/CT. Our CT-free PET attenuation correction method would be beneficial for a wide range of patient populations, especially for pediatric examinations and patients who need multiple scans or who require long-term follow-up. KEY POINTS: • CT is the main source of radiation in PET/CT imaging, especially for total-body PET/CT devices, and reduced radiopharmaceutical doses make the radiation burden from CT more obvious. • The CT-free PET attenuation correction method would be beneficial for patients who need multiple scans or long-term follow-up by reducing additional radiation from redundant anatomical examinations. • The proposed method could directly generate CT-free attenuation-corrected (CTF-AC) total-body PET images, which is beneficial for PET/MRI or PET-only devices lacking CT image poses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningWhole Body ImagingPositron Emission Tomography Computed TomographyHumansFemaleMaleMiddle AgedAdultAgedImage Processing, Computer-AssistedYoung AdultSignal-To-Noise Ratio

Stichwörter der Autor:innen

Deep learningPositron emission tomographyRadiation

Autor:innen und Institutionen

  • Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China.
  • Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Beijing, 101408, China.
  • Department of Nuclear Medicine, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China.
  • Central Research Institute, United Imaging Healthcare Group, Shanghai, 201807, China.
  • Key Laboratory of Biomedical Imaging Science and System, Chinese Academy of Sciences, Shenzhen, 518055, China.
  • Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China. zl.hu@siat.ac.cn.

Förderung

  • National Natural Science Foundation of China
  • Shenzhen Excellent Technological Innovation Talent Training Project of China
  • Shenzhen Science and Technology Innovation Program
  • Shenzhen Medical Research Funds of China

Zitieren

APA

Li, W., Huang, Z., Chen, Z., Jiang, Y., Zhou, C., Zhang, X., Fan, W., Zhao, Y., Zhang, L., Wan, L., Yang, Y., Zheng, H., Liang, D., & Hu, Z. (2024). Learning CT-free attenuation-corrected total-body PET images through deep learning. European Radiology. https://doi.org/10.1007/s00330-024-10647-1

Vancouver

Li W, Huang Z, Chen Z, Jiang Y, Zhou C, Zhang X, et al. Learning CT-free attenuation-corrected total-body PET images through deep learning. European Radiology. 2024. doi:10.1007/s00330-024-10647-1

BibTeX
@article{Li2024,
  author = {Li, Wenbo and Huang, Zhenxing and Chen, Zixiang and Jiang, Yongluo and Zhou, Chao and Zhang, Xu and Fan, Wei and Zhao, Yumo and Zhang, Lulu and Wan, Liwen and Yang, Yongfeng and Zheng, Hairong and Liang, Dong and Hu, Zhanli},
  title = {Learning CT-free attenuation-corrected total-body PET images through deep learning},
  journal = {European Radiology},
  year = {2024},
  doi = {10.1007/s00330-024-10647-1}
}
Kostenlos starten →