EUVIMEDEUVIMED entdecken
Crossref

Eliminating the second CT scan of dual-tracer total-body PET/CT via deep learning-based image synthesis and registration

Yu Lin, Kang Wang, Zhe Zheng, Haojun Yu, Shuguang Chen, WenXin Tang, Yibo He, Huaping Gao, Runjun Yang, Yunzhe Xie, Junjie Yang, Xiaoguang Hou und 2 weitere

European Journal of Nuclear Medicine and Molecular Imaging · 2025

DOI: 10.1007/s00259-025-07113-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2025. Verfasst von Yu Lin und 13 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Institute of Medical Imaging, Shanghai, 200032, China. Hauptthemen laut MEDLINE: Deep Learning, Positron Emission Tomography Computed Tomography, Image Processing, Computer-Assisted, Whole Body Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Innovative Medical Device Application Demonstration Program of Shanghai Municipal Commission of Economy and Informatization, Key Program of Ministry of Industry and Information Technology of China, Chinese National Key Clinical Specialty Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aims to develop and validate a deep learning framework designed to eliminate the second CT scan of dual-tracer total-body PET/CT imaging. METHODS: We retrospectively included three cohorts of 247 patients who underwent dual-tracer total-body PET/CT imaging on two separate days (time interval:1-11 days). Out of these, 167 underwent [68Ga]Ga-DOTATATE/[18F]FDG, 50 underwent [68Ga]Ga-PSMA-11/[18F]FDG, and 30 underwent [68Ga]Ga-FAPI-04/[18F]FDG. A deep learning framework was developed that integrates a registration generative adversarial network (RegGAN) with non-rigid registration techniques. This approach allows for the transformation of attenuation-correction CT (ACCT) images from the first scan into pseudo-ACCT images for the second scan, which are then used for attenuation and scatter correction (ASC) of the second tracer PET images. Additionally, the derived registration transform facilitates dual-tracer image fusion and analysis. The deep learning-based ASC PET images were evaluated using quantitative metrics, including mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM) across the whole body and specific regions. Furthermore, the quantitative accuracy of PET images was assessed by calculating standardized uptake value (SUV) bias in normal organs and lesions. RESULTS: The MAE for whole-body pseudo-ACCT images ranged from 97.64 to 112.59 HU across four tracers. The deep learning-based ASC PET images demonstrated high similarity to the ground-truth PET images. The MAE of SUV for whole-body PET images was 0.06 for [68Ga]Ga-DOTATATE, 0.08 for [68Ga]Ga-PSMA-11, 0.06 for [68Ga]Ga-FAPI-04, and 0.05 for [18F]FDG, respectively. Additionally, the median absolute percent deviation of SUV was less than 2.6% for all normal organs, while the mean absolute percent deviation of SUV was less than 3.6% for lesions across four tracers. CONCLUSION: The proposed deep learning framework, combining RegGAN and non-rigid registration, shows promise in reducing CT radiation dose for dual-tracer total-body PET/CT imaging, with successful validation across multiple tracers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningPositron Emission Tomography Computed TomographyImage Processing, Computer-AssistedWhole Body ImagingHumansRetrospective StudiesMaleAgedMiddle AgedFemaleAdultRadiopharmaceuticals

Stichwörter der Autor:innen

Deep learningDual-tracerImage synthesisRadiation exposureRegistrationTotal-body PET/CT

Substanzen

Radiopharmaceuticals

Autor:innen und Institutionen

  • Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
  • Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China.
  • Institute of Nuclear Medicine, Fudan University, Shanghai, 200032, China.
  • Cancer Prevention and Treatment Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
  • Department of Nuclear Medicine, Fuzhou University Affiliated Provincial Hospital, Fuzhou, 350001, China.
  • Fujian Research Institute of Nuclear Medicine, Fuzhou, 350001, China.

ORCID-Profile: Hongcheng Shi

Förderung

  • Innovative Medical Device Application Demonstration Program of Shanghai Municipal Commission of Economy and Informatization
  • Key Program of Ministry of Industry and Information Technology of China
  • Chinese National Key Clinical Specialty Program
  • National Key Research and Development Program of China

Zitieren

APA

Lin, Y., Wang, K., Zheng, Z., Yu, H., Chen, S., Tang, W., He, Y., Gao, H., Yang, R., Xie, Y., Yang, J., Hou, X., Wang, S., & Shi, H. (2025). Eliminating the second CT scan of dual-tracer total-body PET/CT via deep learning-based image synthesis and registration. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-025-07113-5

Vancouver

Lin Y, Wang K, Zheng Z, Yu H, Chen S, Tang W, et al. Eliminating the second CT scan of dual-tracer total-body PET/CT via deep learning-based image synthesis and registration. European Journal of Nuclear Medicine and Molecular Imaging. 2025. doi:10.1007/s00259-025-07113-5

BibTeX
@article{Lin2025,
  author = {Lin, Yu and Wang, Kang and Zheng, Zhe and Yu, Haojun and Chen, Shuguang and Tang, WenXin and He, Yibo and Gao, Huaping and Yang, Runjun and Xie, Yunzhe and Yang, Junjie and Hou, Xiaoguang and Wang, Shuo and Shi, Hongcheng},
  title = {Eliminating the second CT scan of dual-tracer total-body PET/CT via deep learning-based image synthesis and registration},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2025},
  doi = {10.1007/s00259-025-07113-5}
}
Kostenlos starten →