Sources of variation in multicenter rectal MRI data and their effect on radiomics feature reproducibility
European Radiology · 2022-03 · 32 (3) · 1506-1516
DOI: 10.1007/s00330-021-08251-8 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift European Radiology, online erschienen am 16.10.2021. Verfasst von Niels W Schurink und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The Netherlands Cancer Institute, POB 90203, 1006 BE, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Rectal Neoplasms. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: kwf kankerbestrijding.
Abstract (Originalsprache)
Objectives
To investigate sources of variation in a multicenter rectal cancer MRI dataset focusing on hardware and image acquisition, segmentation methodology, and radiomics feature extraction software.
Methods
T2W and DWI/ADC MRIs from 649 rectal cancer patients were retrospectively acquired in 9 centers. Fifty-two imaging features (14 first-order/6 shape/32 higher-order) were extracted from each scan using whole-volume (expert/non-expert) and single-slice segmentations using two different software packages (PyRadiomics/CapTk). Influence of hardware, acquisition, and patient-intrinsic factors (age/gender/cTN-stage) on ADC was assessed using linear regression. Feature reproducibility was assessed between segmentation methods and software packages using the intraclass correlation coefficient.
Results
Image features differed significantly ( p < 0.001) between centers with more substantial variations in ADC compared to T2W-MRI. In total, 64.3% of the variation in mean ADC was explained by differences in hardware and acquisition, compared to 0.4% by patient-intrinsic factors. Feature reproducibility between expert and non-expert segmentations was good to excellent (median ICC 0.89–0.90). Reproducibility for single-slice versus whole-volume segmentations was substantially poorer (median ICC 0.40–0.58). Between software packages, reproducibility was good to excellent (median ICC 0.99) for most features (first-order/shape/GLCM/GLRLM) but poor for higher-order (GLSZM/NGTDM) features (median ICC 0.00–0.41).
Conclusions
Significant variations are present in multicenter MRI data, particularly related to differences in hardware and acquisition, which will likely negatively influence subsequent analysis if not corrected for. Segmentation variations had a minor impact when using whole volume segmentations. Between software packages, higher-order features were less reproducible and caution is warranted when implementing these in prediction models. Key Points • Features derived from T2W-MRI and in particular ADC differ significantly between centers when performing multicenter data analysis. • Variations in ADC are mainly (> 60%) caused by hardware and image acquisition differences and less so (< 1%) by patient- or tumor-intrinsic variations. • Features derived using different image segmentations (expert/non-expert) were reproducible, provided that whole-volume segmentations were used. When using different feature extraction software packages with similar settings, higher-order features were less reproducible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, The Netherlands Cancer Institute, POB 90203, 1006 BE, Amsterdam, The Netherlands.
- GROW School for Oncology & Developmental Biology, University of Maastricht, Maastricht, The Netherlands.
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
- Department of Epidemiology and Biostatistics, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
- Department of Radiology, Acad. F. Todua Medical Center, Research Institute of Clinical Medicine, Tbilisi, Georgia.
- Department of Radiology, Maastricht University Medical Centre, Maastricht, The Netherlands.
Förderung
- kwf kankerbestrijding
Zitieren
APA
Schurink, N. W., van Kranen, S. R., Roberti, S., van Griethuysen, J. J. M., Bogveradze, N., Castagnoli, F., El Khababi, N., Bakers, F. C. H., de Bie, S. H., Bosma, G. P. T., Cappendijk, V. C., Geenen, R. W. F., Neijenhuis, P. A., Peterson, G. M., Veeken, C. J., Vliegen, R. F. A., Beets-Tan, R. G. H., & Lambregts, D. M. J. (2022). Sources of variation in multicenter rectal MRI data and their effect on radiomics feature reproducibility. European Radiology, 32(3), 1506-1516. https://doi.org/10.1007/s00330-021-08251-8
Vancouver
Schurink NW, van Kranen SR, Roberti S, van Griethuysen JJM, Bogveradze N, Castagnoli F, et al. Sources of variation in multicenter rectal MRI data and their effect on radiomics feature reproducibility. European Radiology. 2022;32(3):1506-1516. doi:10.1007/s00330-021-08251-8
BibTeX
@article{Schurink2022,
author = {Schurink, Niels W and van Kranen, Simon R and Roberti, Sander and van Griethuysen, Joost J M and Bogveradze, Nino and Castagnoli, Francesca and El Khababi, Najim and Bakers, Frans C H and de Bie, Shira H and Bosma, Gerlof P T and Cappendijk, Vincent C and Geenen, Remy W F and Neijenhuis, Peter A and Peterson, Gerald M and Veeken, Cornelis J and Vliegen, Roy F A and Beets-Tan, Regina G H and Lambregts, Doenja M J},
title = {Sources of variation in multicenter rectal MRI data and their effect on radiomics feature reproducibility},
journal = {European Radiology},
year = {2022},
volume = {32},
number = {3},
pages = {1506--1516},
doi = {10.1007/s00330-021-08251-8}
}
EUVIMED