Clinical Breast MRI ‐based Radiomics for Distinguishing Benign and Malignant Lesions: An Analysis of Sequences and Enhanced Phases
Journal of Magnetic Resonance Imaging · 2024
DOI: 10.1002/jmri.29150 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Guangsong Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, Fujian, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Magnetic Resonance Imaging, Breast, Contrast Media. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: The Scientific Research Foundation for Advanced Talents, Xiang'an Hospital of Xiamen University.
Abstract (Originalsprache)
Background
Previous studies have used different imaging sequences and different enhanced phases for breast lesion calsification in radiomics. The optimal sequence and contrast enhanced phase is unclear.
Purpose
To identify the optimal magnetic resonance imaging (MRI) radiomics model for lesion clarification, and to simulate its incremental value for multiparametric MRI (mpMRI)‐guided biopsy. Study Type Retrospective. Population 329 female patients (138 malignant, 191 benign), divided into a training set (first site, n = 192) and an independent test set (second site, n = 137). Field Strength/Sequence 3.0‐T, fast spoiled gradient‐echo and fast spin‐echo T1‐weighted imaging (T1WI), fast spin‐echo T2‐weighted imaging (T2WI), echo‐planar diffusion‐weighted imaging (DWI), and fast spoiled gradient‐echo contrast‐enhanced MRI (CE‐MRI). Assessment Two breast radiologists with 3 and 10 years' experience developed radiomics model on CE‐MRI, CE‐MRI + DWI, CE‐MRI + DWI + T2WI, CE‐MRI + DWI + T2WI + T1WI at each individual phase (P) and for multiple combinations of phases. The optimal radiomics model (Rad‐score) was identified as having the highest area under the receiver operating characteristic curve (AUC) in the test set. Specificity was compared between a traditional mpMRI model and an integrated model (mpMRI + Rad‐score) at sensitivity >98%. Statistical Tests Wilcoxon paired‐samples signed rank test, Delong test, McNemar test. Significance level was 0.05 and Bonferroni method was used for multiple comparisons ( P = 0.007, 0.05/7).
Results
For radiomics models, CE‐MRI/P3 + DWI + T2WI achieved the highest performance in the test set (AUC = 0.888, 95% confidence interval: 0.833–0.944). The integrated model had significantly higher specificity (55.3%) than the mpMRI model (31.6%) in the test set with a sensitivity of 98.4%. Data Conclusion The CE‐MRI/P3 + DWI + T2WI model is the optimized choice for breast lesion classification in radiomics, and has potential to reduce benign biopsies (100%–specificity) from 68.4% to 44.7% while retaining sensitivity >98%. Level of Evidence 3 Technical Efficacy Stage 2
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, Fujian, China.
- Department of Radiology, The Second Affiliated Hospital of Xiamen Medical College, Xiamen, Fujian, China.
- Xiamen Key Laboratory of Endocrine-Related Cancer Precision Medicine, Xiang'an Hospital of Xiamen university, Xiamen, Fujian, China.
ORCID-Profile: Guangsong Wang, Dafa Shi
Förderung
- The Scientific Research Foundation for Advanced Talents, Xiang'an Hospital of Xiamen University
Zitieren
APA
Wang, G., Guo, Q., Shi, D., Zhai, H., Luo, W., Zhang, H., Ren, Z., Yan, G., & Ren, K. (2024). Clinical Breast MRI ‐based Radiomics for Distinguishing Benign and Malignant Lesions: An Analysis of Sequences and Enhanced Phases. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29150
Vancouver
Wang G, Guo Q, Shi D, Zhai H, Luo W, Zhang H, et al. Clinical Breast MRI ‐based Radiomics for Distinguishing Benign and Malignant Lesions: An Analysis of Sequences and Enhanced Phases. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29150
BibTeX
@article{Wang2024,
author = {Wang, Guangsong and Guo, Qiu and Shi, Dafa and Zhai, Huige and Luo, Wenbin and Zhang, Haoran and Ren, Zhendong and Yan, Gen and Ren, Ke},
title = {Clinical Breast MRI ‐based Radiomics for Distinguishing Benign and Malignant Lesions: An Analysis of Sequences and Enhanced Phases},
journal = {Journal of Magnetic Resonance Imaging},
year = {2024},
doi = {10.1002/jmri.29150}
}
EUVIMED