Detection of Endoleak after Endovascular Aortic Repair through Deep Learning Based on Non-contrast CT
CardioVascular and Interventional Radiology · 2024-09 · 47 (9) · 1267-1275
DOI: 10.1007/s00270-024-03805-x ↗Kurz gefasst
Validierungsstudie in der Zeitschrift CardioVascular and Interventional Radiology, online erschienen am 08.07.2024. Verfasst von Qingqi Yang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China. Hauptthemen laut MEDLINE: Endoleak, Deep Learning, Endovascular Procedures, Computed Tomography Angiography. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: To develop and validate a deep learning model for detecting post-endovascular aortic repair (EVAR) endoleak from non-contrast CT. METHODS: This retrospective study involved 245 patients who underwent EVAR between September 2016 and December 2022. All patients underwent both non-enhanced and enhanced follow-up CT. The presence of endoleak was evaluated based on computed tomography angiography (CTA) and radiology reports. First, the aneurysm sac was segmented, and radiomic features were extracted on non-contrast CT. Statistical analysis was conducted to investigate differences in shape and density characteristics between aneurysm sacs with and without endoleak. Subsequently, a deep learning model was trained to generate predicted segmentation of the endoleak. A binary decision was made based on whether the model produced a segmentation to detect the presence of endoleak. The absence of a predicted segmentation indicated no endoleak, while the presence of a predicted segmentation indicated endoleak. Finally, the performance of the model was evaluated by comparing the predicted segmentation with the reference segmentation obtained from CTA. Model performance was assessed using metrics such as dice similarity coefficient, sensitivity, specificity, and the area under the curve (AUC). RESULTS: This study finally included 85 patients with endoleak and 82 patients without endoleak. Compared to patients without endoleak, patients with endoleak had higher CT values and greater dispersion. The AUC in validation group was 0.951, dice similarity coefficient was 0.814, sensitivity was 0.877, and specificity was 0.884. CONCLUSION: This deep learning model based on non-contrast CT can detect endoleak after EVAR with high sensitivity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
- School of Medicine, Sun Yat-Sen University, Guangzhou, China.
- Department of Medical Imaging, The Second Affiliated Hospital, Guangzhou Medical University, Guangzhou, China.
- Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China. wurd5@mail.sysu.edu.cn.
Zitieren
APA
Yang, Q., Hu, J., Luo, Y., Jia, D., Chen, N., Yao, C., & Wu, R. (2024). Detection of Endoleak after Endovascular Aortic Repair through Deep Learning Based on Non-contrast CT. CardioVascular and Interventional Radiology, 47(9), 1267-1275. https://doi.org/10.1007/s00270-024-03805-x
Vancouver
Yang Q, Hu J, Luo Y, Jia D, Chen N, Yao C, et al. Detection of Endoleak after Endovascular Aortic Repair through Deep Learning Based on Non-contrast CT. CardioVascular and Interventional Radiology. 2024;47(9):1267-1275. doi:10.1007/s00270-024-03805-x
BibTeX
@article{Yang2024,
author = {Yang, Qingqi and Hu, Jinglang and Luo, Yingqi and Jia, Dongdong and Chen, Nuo and Yao, Chen and Wu, Ridong},
title = {Detection of Endoleak after Endovascular Aortic Repair through Deep Learning Based on Non-contrast CT},
journal = {CardioVascular and Interventional Radiology},
year = {2024},
volume = {47},
number = {9},
pages = {1267--1275},
doi = {10.1007/s00270-024-03805-x}
}
EUVIMED