A Prospective, Multicentre Registry on Thirty Day and One Year Outcomes of the E-liac Stent Graft System in Patients with Unilateral or Bilateral Aorto-iliac or Iliac Aneurysms: The PLIANTII Study

Alexander Oberhuber, Sebastien Deglise, Olaf Richter, Vladimir Makaloski, Umberto Bracale, Giacomo Isernia, Roland Tines, Alessandro Cappelli, Bernhard Dorweiler, Jan Brunkwall, PLIANTII Study Collaboration

European Journal of Vascular and Endovascular Surgery · 2025-06 · 69 (6) · 847-854

DOI: 10.1016/j.ejvs.2025.02.029 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2025-06. Verfasst von Alexander Oberhuber und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular and Endovascular Surgery, University of Muenster, Muenster, Germany. Hauptthemen laut MEDLINE: Iliac Aneurysm, Stents, Blood Vessel Prosthesis, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The aim of this study was to prospectively evaluate the real world outcomes of the E-liac stent graft system used to electively treat common iliac artery aneurysms, either unilaterally or bilaterally. METHODS: PLIANTII is a prospective, observational, non-randomised, multicentre study. The E-liac stent graft system was implanted for the treatment of iliac artery aneurysms in 295 patients across 30 European centres between September 2018 and September 2023, with 236 patients also treated for a concomitant infrarenal abdominal aortic aneurysm. The endpoints, including clinical outcomes, are reported up to the twelve month follow up. The primary endpoint was a composite of freedom from type I or III endoleak plus patency of the external (EIA) and internal iliac arteries (IIA) on the E-liac implantation side(s) at the twelve month follow up. Technical success was defined as successful access and deployment of the stent graft without surgical conversion, death, type I or III endoleak, or graft limb occlusion, assessed at discharge or 30 days. Clinical success, evaluated at twelve months, also included the absence of stent graft infection and iliac aneurysm rupture. RESULTS: Two hundred and ninetyfive consecutive patients (95.6% male; mean age 72.7 years) were included. The primary endpoint was achieved in 91.8%. No death was recorded within 30 days of implantation, and seven deaths had occurred at twelve months. The Kaplan-Meier estimated survival rate up to the twelve month follow up visit was 96.7 ± 1.2%. Technical success at discharge or 30 days was achieved in 93.1% of patients, while clinical success at twelve months was achieved in 91.2%. There were 5.4% re-interventions within 30 days and 12.9% within twelve months. The Kaplan-Meier estimated freedom from E-liac related re-intervention up to the twelve month follow up visit was 91.3 ± 1.8%. The primary patency rate at discharge or 30 day visit was 97.6% (284/291) for the EIA and 96.2% (280/291) for the IIA, whereas Kaplan-Meier estimated freedom from occlusion up to twelve months was 94.5 ± 1.6% for the EIA and 94.7 ± 1.5% for the IIA. CONCLUSION: The one year data from the PLIANTII study show that treatment with the E-liac stent graft system is safe and results in good technical and clinical success rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Iliac AneurysmStentsBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationEndovascular ProceduresAortic Aneurysm, AbdominalHumansMaleFemaleAgedProspective StudiesRegistriesTreatment OutcomeMiddle AgedProsthesis DesignAged, 80 and overEndoleakTime FactorsVascular PatencyEurope

Stichwörter der Autor:innen

E-liac stent graft systemEVAREndovascular iliac aneurysm repairIliac artery aneurysmIliac branch device

Autor:innen und Institutionen

  • Department of Vascular and Endovascular Surgery, University of Muenster, Muenster, Germany.
  • Services of Vascular Surgery, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland.
  • Department of Vascular Surgery, Ev. Diakonissenkrankenhaus Leipzig, Leipzig, Germany.
  • Department of Cardiovascular Surgery, Swiss Cardiovascular Centre, University Hospital of Bern (Inselspital), University of Bern, Bern, Switzerland.
  • Department of Public Health, University of Naples "Federico II", Naples, Italy.
  • Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia University Hospital, Perugia, Italy.

Zitieren

APA

Oberhuber, A., Deglise, S., Richter, O., Makaloski, V., Bracale, U., Isernia, G., Tines, R., Cappelli, A., Dorweiler, B., Brunkwall, J., & PLIANTII Study Collaboration (2025). A Prospective, Multicentre Registry on Thirty Day and One Year Outcomes of the E-liac Stent Graft System in Patients with Unilateral or Bilateral Aorto-iliac or Iliac Aneurysms: The PLIANTII Study. European Journal of Vascular and Endovascular Surgery, 69(6), 847-854. https://doi.org/10.1016/j.ejvs.2025.02.029

Vancouver

Oberhuber A, Deglise S, Richter O, Makaloski V, Bracale U, Isernia G, et al. A Prospective, Multicentre Registry on Thirty Day and One Year Outcomes of the E-liac Stent Graft System in Patients with Unilateral or Bilateral Aorto-iliac or Iliac Aneurysms: The PLIANTII Study. European Journal of Vascular and Endovascular Surgery. 2025;69(6):847-854. doi:10.1016/j.ejvs.2025.02.029

BibTeX
@article{Oberhuber2025,
  author = {Oberhuber, Alexander and Deglise, Sebastien and Richter, Olaf and Makaloski, Vladimir and Bracale, Umberto and Isernia, Giacomo and Tines, Roland and Cappelli, Alessandro and Dorweiler, Bernhard and Brunkwall, Jan and PLIANTII Study Collaboration, PLIANTII Study Collaboration},
  title = {A Prospective, Multicentre Registry on Thirty Day and One Year Outcomes of the E-liac Stent Graft System in Patients with Unilateral or Bilateral Aorto-iliac or Iliac Aneurysms: The PLIANTII Study},
  journal = {European Journal of Vascular and Endovascular Surgery},
  year = {2025},
  volume = {69},
  number = {6},
  pages = {847--854},
  doi = {10.1016/j.ejvs.2025.02.029}
}
Kostenlos starten →