EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Safety of Depth-Adjusted Intravenous Anesthesia in Office-Based Aesthetic Surgery: A One-Month Prospective Study of 135 Consecutive Cases

Keisuke Matsumura, Takahiko Tamura, Kohki Okumura, Reiko Kiuchi, Hiroo Teranishi

Aesthetic Plastic Surgery · 2026-08 · 50 (15) · 6548-6554

DOI: 10.1007/s00266-026-05922-z ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Aesthetic Plastic Surgery, online erschienen am 27.05.2026. Verfasst von Keisuke Matsumura und 4 weiteren Autor:innen. Beteiligte Einrichtung: TCB Umeda Osaka Ekimae Clinic, Tokyo Chuo Beauty Clinic K's Square, Building 3F, 2-8-15 Sonezaki, Kita-ku, Osaka-City, Osaka, 530-0057, Japan. dr.mat…. Hauptthemen laut MEDLINE: Ambulatory Surgical Procedures, Anesthesia, Intravenous, Plastic Surgery Procedures. Die Arbeit nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Office-based aesthetic surgery frequently relies on intravenous anesthesia to balance intraoperative comfort with rapid recovery. While large series suggest low complication rates, prospective data on patient-reported outcomes under standardized, depth-adjusted protocols remain limited. This study prospectively evaluated safety, satisfaction, recall, and recovery using the specialist-led UMEDA protocol. METHODS: In a single-center, prospective observational study, all consecutive adults undergoing office-based aesthetic procedures between May 1-31, 2025 were analyzed (N = 135). Intravenous anesthesia followed the UMEDA (Ultra-safe Method for Elective Depth-adjusted Anesthesia) protocol; monitoring included automated noninvasive blood pressure, heart rate, and pulse oximetry at 5-min intervals. Anesthesia was predominantly propofol-based (133/135), with midazolam used only in patients with a history of allergy to propofol formulation components (2/135). Primary endpoint was patient satisfaction (5-point Likert). Secondary endpoints were intraoperative recall, recovery time, and major cardiorespiratory events. Two prespecified multivariable logistic regressions examined predictors of (1) high satisfaction (score = 5) and (2) continuous recall. RESULTS: No major cardiorespiratory events occurred. Median satisfaction was 5 [IQR 4-5]; 68.1% rated 5. Intraoperative recall was "none" in 38.5%, "induction/emergence only" in 47.4%, and "continuous" in 14.1%. Median recovery time was 22 min [13.0-36.0]. In the satisfaction model, female sex independently predicted high satisfaction (aOR 3.31; 95% CI 1.04-10.50; p = 0.042); age, operative time, recovery time, weight-adjusted propofol dose, multiple procedures, and continuous infusion were not significant (all VIF

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ambulatory Surgical ProceduresAnesthesia, IntravenousPlastic Surgery ProceduresHumansFemaleMaleProspective StudiesAdultMiddle AgedPatient SatisfactionPropofolAnesthetics, IntravenousAnesthesia Recovery Period

Stichwörter der Autor:innen

Aesthetic surgeryIntravenous anesthesiaPatient satisfaction

Substanzen

PropofolAnesthetics, Intravenous

Autor:innen und Institutionen

  • TCB Umeda Osaka Ekimae Clinic, Tokyo Chuo Beauty Clinic K's Square, Building 3F, 2-8-15 Sonezaki, Kita-ku, Osaka-City, Osaka, 530-0057, Japan. dr.matsumura.keisuke@tcb.or.jp.
  • TCB Umeda Osaka Ekimae Clinic, Tokyo Chuo Beauty Clinic K's Square, Building 3F, 2-8-15 Sonezaki, Kita-ku, Osaka-City, Osaka, 530-0057, Japan.

Zitieren

APA

Matsumura, K., Tamura, T., Okumura, K., Kiuchi, R., & Teranishi, H. (2026). Safety of Depth-Adjusted Intravenous Anesthesia in Office-Based Aesthetic Surgery: A One-Month Prospective Study of 135 Consecutive Cases. Aesthetic Plastic Surgery, 50(15), 6548-6554. https://doi.org/10.1007/s00266-026-05922-z

Vancouver

Matsumura K, Tamura T, Okumura K, Kiuchi R, Teranishi H. Safety of Depth-Adjusted Intravenous Anesthesia in Office-Based Aesthetic Surgery: A One-Month Prospective Study of 135 Consecutive Cases. Aesthetic Plastic Surgery. 2026;50(15):6548-6554. doi:10.1007/s00266-026-05922-z

BibTeX
@article{Matsumura2026,
  author = {Matsumura, Keisuke and Tamura, Takahiko and Okumura, Kohki and Kiuchi, Reiko and Teranishi, Hiroo},
  title = {Safety of Depth-Adjusted Intravenous Anesthesia in Office-Based Aesthetic Surgery: A One-Month Prospective Study of 135 Consecutive Cases},
  journal = {Aesthetic Plastic Surgery},
  year = {2026},
  volume = {50},
  number = {15},
  pages = {6548--6554},
  doi = {10.1007/s00266-026-05922-z}
}
Kostenlos starten →