EUVIMEDEUVIMED entdecken
Klinische Studie

Ultrasound Measurement of Dynamic Changes in Optic Nerve Sheath Diameter During Liposuction Surgery: A Prospective Clinical Trial

Wenli Xu, Chunmei Chen, Ye Wang, Lei Wang, Dong Yang

Aesthetic Plastic Surgery · 2026-06 · 50 (11) · 4126-4134

DOI: 10.1007/s00266-026-05807-1 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Aesthetic Plastic Surgery, online erschienen am 13.04.2026. Verfasst von Wenli Xu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No.33, Ba Da Chu Road, …. Hauptthemen laut MEDLINE: Optic Nerve, Lipectomy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Liposuction surgery is often performed with patients either in a supine or prone position. The prone position can potentially increase the intracranial pressure, with the risk of adverse outcomes. Ultrasound can be used to measure the optic nerve sheath diameter (ONSD), which is a validated non-invasive marker for assessing intracranial pressure changes. However, the use of ultrasound to measure the ONSD has not been previously reported in liposuction surgery. METHODS: A prospective clinical trial was conducted in patients undergoing liposuction. Eligible patients were assigned to either a prone position group or supine position group. The patients' ONSD and vital signs levels were recorded at various time points, namely upon awakening, 30 min, and 60 min after anesthesia induction, and immediately before the conclusion of surgery while in the supine position. The incidence of 24-hour postoperative nausea and vomiting (PONV) was also recorded. RESULTS: In total, 47 patients were included in the study and were assigned to a prone group (25 patients) or supine group (22 patients), respectively. In the prone group, the ONSD values were higher at 30 min and 60 min after anesthesia than before anesthesia (p < 0.05). Compared with the supine group, the prone group had a significantly enlarged ONSD after anesthesia (p < 0.05). There was no statistically significant difference in PONV between the two groups. CONCLUSION: Ultrasound can be used to dynamically monitor the ONSD during liposuction. Patients in the prone position had a statistically significant increased ONSD compared with those in the supine position. LEVEL OF EVIDENCE II: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Optic NerveLipectomyHumansProspective StudiesFemaleAdultProne PositionUltrasonographySupine PositionMiddle AgedPatient PositioningMale

Stichwörter der Autor:innen

LiposuctionOptic nerve sheath diameterProne positionUltrasonography

Autor:innen und Institutionen

  • Department of Anesthesiology, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No.33, Ba Da Chu Road, Shi Jing Shan, Beijing, 100144, China.
  • Department of Anesthesiology, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No.33, Ba Da Chu Road, Shi Jing Shan, Beijing, 100144, China. yangdongmazui@163.com.

Zitieren

APA

Xu, W., Chen, C., Wang, Y., Wang, L., & Yang, D. (2026). Ultrasound Measurement of Dynamic Changes in Optic Nerve Sheath Diameter During Liposuction Surgery: A Prospective Clinical Trial. Aesthetic Plastic Surgery, 50(11), 4126-4134. https://doi.org/10.1007/s00266-026-05807-1

Vancouver

Xu W, Chen C, Wang Y, Wang L, Yang D. Ultrasound Measurement of Dynamic Changes in Optic Nerve Sheath Diameter During Liposuction Surgery: A Prospective Clinical Trial. Aesthetic Plastic Surgery. 2026;50(11):4126-4134. doi:10.1007/s00266-026-05807-1

BibTeX
@article{Xu2026,
  author = {Xu, Wenli and Chen, Chunmei and Wang, Ye and Wang, Lei and Yang, Dong},
  title = {Ultrasound Measurement of Dynamic Changes in Optic Nerve Sheath Diameter During Liposuction Surgery: A Prospective Clinical Trial},
  journal = {Aesthetic Plastic Surgery},
  year = {2026},
  volume = {50},
  number = {11},
  pages = {4126--4134},
  doi = {10.1007/s00266-026-05807-1}
}
Kostenlos starten →