Clinical evaluation of the safety and efficacy of a 1060 nm diode laser for non‐invasive fat reduction of the flanks
Journal of Cosmetic Dermatology · 2023
DOI: 10.1111/jocd.15954 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cosmetic Dermatology, 2023. Verfasst von Alison Kang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Laser and Skin Surgery Center of Northern California, Sacramento, California, USA. Hauptthemen laut MEDLINE: Lasers, Semiconductor, Subcutaneous Fat, Lipectomy, Low-Level Light Therapy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Laser hyperthermia‐induced lipolysis is a non‐invasive method of localized fat treatment. Non‐invasive approaches could be an option for a growing number of patients who are risk‐averse and are seeking out non‐invasive alternatives to surgical procedures such as liposuction. This study evaluated the safety and efficacy of a 1060 nm diode laser for the non‐invasive fat reduction of the flanks.
Methods
A total of 30 subjects were enrolled in this prospective, single center study. Subjects received one 25‐min treatment with a 1060 nm diode laser to both flanks. Follow‐up visits were conducted at 6 and 12 weeks after the last treatment. Ultrasound adipose thickness, body weight, and circumference measurements were taken at baseline and at the 6‐ and 12‐week follow‐up visits. Subject satisfaction was assessed using a self‐assessment of fat reduction, pain, and tolerability scales, and a subject satisfaction questionnaire. Safety was assessed via the presence or absence of any adverse events.
Results
The average age of subjects was 47.3 years. A total of 27 subjects completed the treatment and returned for both follow‐up visits. An adipose reduction of 7.57 ± 1.15% at 6 weeks post‐treatment ( p < 0.0001) was measured using ultrasound. High subject satisfaction was seen, with 74% of subjects reporting being either “satisfied” or “very satisfied” with their results on a 5‐point Likert Scale. Eighty‐two percent of subjects stated they would recommend the treatment to their friends. All subjects had either mild or moderate pain, with 52% of subjects rating their pain as “mild” (1–3), while 48% rated their pain as moderate (4–7) on the Wong‐Baker Scale.
Conclusions
A single treatment with a 1060 nm diode laser was both safe and effective in reducing unwanted fat in the flanks without any unanticipated adverse events. Subjects described their treatment pain as mild or moderate and were highly satisfied with their treatment outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laser and Skin Surgery Center of Northern California, Sacramento, California, USA.
- Department of Plastic Surgery, UT Southwestern Medical Center, Dallas, Texas, USA.
Zitieren
APA
Kang, A., Kislevitz, M., Wamsley, C., Barillas, J., Hoopman, J., Kenkel, J., & Kilmer, S. (2023). Clinical evaluation of the safety and efficacy of a 1060 nm diode laser for non‐invasive fat reduction of the flanks. Journal of Cosmetic Dermatology. https://doi.org/10.1111/jocd.15954
Vancouver
Kang A, Kislevitz M, Wamsley C, Barillas J, Hoopman J, Kenkel J, et al. Clinical evaluation of the safety and efficacy of a 1060 nm diode laser for non‐invasive fat reduction of the flanks. Journal of Cosmetic Dermatology. 2023. doi:10.1111/jocd.15954
BibTeX
@article{Kang2023,
author = {Kang, Alison and Kislevitz, Mikaela and Wamsley, Christine and Barillas, Jennifer and Hoopman, John and Kenkel, Jeffrey and Kilmer, Suzanne},
title = {Clinical evaluation of the safety and efficacy of a 1060 nm diode laser for non‐invasive fat reduction of the flanks},
journal = {Journal of Cosmetic Dermatology},
year = {2023},
doi = {10.1111/jocd.15954}
}
EUVIMED