Intraoperative six-axis loads during direct anterior approach total hip arthroplasty using a leg positioner: quantitative patterns across manoeuvres
International Orthopaedics · 2026-12 · 50 (12) · 3171-3179
DOI: 10.1007/s00264-026-07040-6 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift International Orthopaedics, online erschienen am 21.09.2026. Verfasst von Eiji Iwasaki und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Juntendo University, Tokyo, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Joint, Patient Positioning. Die Arbeit nennt 34 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: The direct anterior approach (DAA) for total hip arthroplasty (THA) commonly uses leg positioners to facilitate femoral exposure, but intraoperative lower-limb loading during these manoeuvres remains poorly understood. This study quantitatively assessed six-axis loads during femoral preparation in leg positioner-assisted DAA-THA. METHODS: This prospective observational biomechanical study included 95 hips undergoing primary DAA-THA using a leg positioner. A six-axis force sensor mounted on the operative boot recorded forces (Fx, Fy, Fz) and moments (Mx, My, Mz) at baseline and at two predefined static endpoint measurement points: the extension endpoint and the final stem position after adduction. Values were expressed relative to baseline and represented static endpoint measurements rather than peak values during dynamic manoeuvres. Measurements were standardised to a right-sided coordinate system. Repeated-measures analysis of variance with Bonferroni-corrected post hoc paired comparisons was used. RESULTS: At the extension endpoint, distal traction force was greatest (Fz; 170.6 ± 51.9 N). At the final stem position after adduction, distal traction force decreased compared with the extension endpoint but remained elevated relative to baseline (126.9 ± 45.7 N), and Mx showed the greatest magnitude among the moment components. The maximum endpoint Fz relative to baseline was recorded at the extension endpoint (322.8 N). No significant associations were found between final-position Fz and age, sex, height, weight, body mass index, or diagnosis. Mean stem rasping time was 10 min 48 s ± 4 min 28 s (648 ± 268 s). CONCLUSION: During leg positioner-assisted DAA-THA, the extension endpoint generated the highest distal traction force, whereas the final stem position after adduction was associated with residual distal traction force and a greater magnitude of Mx.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Juntendo University, Tokyo, Japan.
- Department of Orthopaedic Surgery, Juntendo University, Tokyo, Japan. tobaba@juntendo.ac.jp.
- Shibaura Institute of Technology, Saitama, Japan.
ORCID-Profile: Ken Tashiro
Zitieren
APA
Iwasaki, E., Baba, T., Tashiro, K., Hayashi, K., Watari, T., Shoji, R., Hanafusa, A., & Ishijima, M. (2026). Intraoperative six-axis loads during direct anterior approach total hip arthroplasty using a leg positioner: quantitative patterns across manoeuvres. International Orthopaedics, 50(12), 3171-3179. https://doi.org/10.1007/s00264-026-07040-6
Vancouver
Iwasaki E, Baba T, Tashiro K, Hayashi K, Watari T, Shoji R, et al. Intraoperative six-axis loads during direct anterior approach total hip arthroplasty using a leg positioner: quantitative patterns across manoeuvres. International Orthopaedics. 2026;50(12):3171-3179. doi:10.1007/s00264-026-07040-6
BibTeX
@article{Iwasaki2026,
author = {Iwasaki, Eiji and Baba, Tomonori and Tashiro, Ken and Hayashi, Koju and Watari, Taiji and Shoji, Risa and Hanafusa, Akihiko and Ishijima, Muneaki},
title = {Intraoperative six-axis loads during direct anterior approach total hip arthroplasty using a leg positioner: quantitative patterns across manoeuvres},
journal = {International Orthopaedics},
year = {2026},
volume = {50},
number = {12},
pages = {3171--3179},
doi = {10.1007/s00264-026-07040-6}
}
EUVIMED