Trabecular metal cups versus reconstruction cages for primary total hip arthroplasty in the irradiated acetabulum: a nine year comparative cohort study
International Orthopaedics · 2026
DOI: 10.1007/s00264-026-07004-w ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Orthopaedics, 2026. Verfasst von Yu-Chih Lin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Acetabulum, Hip Prosthesis. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Chang Gung Memorial Hospital.
Abstract (Originalsprache)
PURPOSE: Acetabular reconstruction for primary total hip arthroplasty (THA) after pelvic radiotherapy is difficult because irradiated bone integrates poorly, and the optimal fixation method remains undefined, with comparative data lacking. We compared trabecular metal (TM) cups with reconstruction cages for implant survivorship and function. METHODS: We retrospectively reviewed all 40 patients (40 hips) who underwent primary THA after pelvic radiotherapy at a single centre during 2008-2019 (20 TM cups, 20 reconstruction cages) in this unmatched cohort. Groups were compared with unpaired tests; survivorship was estimated by Kaplan-Meier (log-rank), with Firth penalized Cox regression and sensitivity analyses. The primary outcome was survivorship free from aseptic loosening; secondary outcomes were all-cause revision, complications and the Harris Hip Score (HHS). RESULTS: The groups were similar in age, sex and radiation dose; follow-up was longer in the cage group (median 9.7 versus 8.4 years; p = 0.036). Ten-year survivorship free from aseptic loosening was 100% (TM) versus 88.2% (cage) (95% CI 59.9%-97.0%; p = 0.182; Firth hazard ratio 3.42, 95% CI 0.52-22.45); all-cause revision-free survivorship was 100% versus 78.5% (95% CI 51.8%-91.4%; p = 0.040; hazard ratio 5.18, 95% CI 0.82-32.74); four of 20 cage hips were revised. Postoperative HHS was higher for TM cups (88.9 versus 81.8, p < 0.001), below the minimal clinically important difference. Complications occurred in 10% versus 25% (p = 0.407). CONCLUSION: In this small, retrospective cohort, TM cups showed numerically higher survivorship and function than reconstruction cages, but only the revision comparison was significant; the study is underpowered elsewhere. These hypothesis-generating findings require confirmation in larger, multicentre cohorts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan.
- Department of Orthopaedic Surgery, Keelung Chang Gung Memorial Hospital, Keelung, Taiwan. mr5181@adm.cgmh.org.tw.
- Department of Orthopaedic Surgery, Keelung Chang Gung Memorial Hospital, Keelung, Taiwan. b101095149@tmu.edu.tw.
Förderung
- Chang Gung Memorial Hospital
Zitieren
APA
Lin, Y. C., Lee, S. H., Peng, S. H., Hu, C. C., Chen, W. C., & Lau, N. C. (2026). Trabecular metal cups versus reconstruction cages for primary total hip arthroplasty in the irradiated acetabulum: a nine year comparative cohort study. International Orthopaedics. https://doi.org/10.1007/s00264-026-07004-w
Vancouver
Lin YC, Lee SH, Peng SH, Hu CC, Chen WC, Lau NC. Trabecular metal cups versus reconstruction cages for primary total hip arthroplasty in the irradiated acetabulum: a nine year comparative cohort study. International Orthopaedics. 2026. doi:10.1007/s00264-026-07004-w
BibTeX
@article{Lin2026,
author = {Lin, Yu-Chih and Lee, Sheng-Hsun and Peng, Shih-Hui and Hu, Chih-Chien and Chen, Wei-Chih and Lau, Ngi-Chiong},
title = {Trabecular metal cups versus reconstruction cages for primary total hip arthroplasty in the irradiated acetabulum: a nine year comparative cohort study},
journal = {International Orthopaedics},
year = {2026},
doi = {10.1007/s00264-026-07004-w}
}
EUVIMED